5.11
Automatic acceleration valve
Operation of the automatic acceleration: The acceleration is always engaged. The motion slows down and
the splitting force increases as the splitting resistance rises to over 120 bar (factory setting). The limit
value for slowing down the splitting motion can be changed as follows:
1. Remove the locking
bolt of the valve unit's
cover.
2. Open the valve
unit's cover.
3. Open the locking
nut
of
the
acceleration valve's
adjustment bolt.
4. Use the adjustment bolt to set the pressure to
the desired level.
Adjustment directions:
Closed
– the motion slows down at
higher resistance
Open
– the motion slows down at lower
resistance
1 rotation
= approx.
10 bar
6. When the splitting
beam returns to the
initial position, the
valve lever forcing
the spring turns to
the left and forces
the spring to press
the jointed lever to
the right.
7. The depressed
trigger rod stops the
jointed lever in the
middle position
halting the splitting
system.