background image

R3-PD16A

P. 10 / 10

EM-8397 Rev.1

M-SYSTEM WARRANTY

M-System warrants such new M-System product which it manufactures to be free from defects in materials and workmanship during the 36-month period following the date that such 
product was originally purchased if such product has been used under normal operating conditions and properly maintained, M-System’s sole liability, and purchaser’s exclusive 
remedies, under this warranty are, at M-System’s option, the repair, replacement or refund of the purchase price of any M-System product which is defective under the terms of this 
warranty.  To submit a claim under this warranty, the purchaser must return, at its expense, the defective M-System product to the below address together with a copy of its original 
sales invoice.
THIS IS THE ONLY WARRANTY APPLICABLE TO M-SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  M-SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL, INCIDENTAL OR 
SPECIAL DAMAGES OF ANY KIND WHATSOEVER.
M-System Co., Ltd., 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN, Phone: (06) 6659-8201, Fax: (06) 6659-8510, E-mail: [email protected]

WIRING INSTRUCTIONS

 SOLDERLESS TERMINAL  mm (inch)

Refer  to  the  drawing  below  for  recommended  ring  tongue 

terminal size.  Spade tongue type is also applicable.  Solder-

less terminals with insulation sleeve do not fit.  Applicable 
wire size: 0.3 – 0.5 mm

2

3.2 (.13) dia.

4 min.

(.16)

12 (.47) max.

6 max.

(.24)

3 (.12) max.

1

11
12
13
14
15
16
17
18
19
20

2
3
4
5
6
7
8
9

10

130 (5.12)

27.5 (1.08)

109 (4.29)

POSITIONING

GUIDE

TERMINAL

COVER

20–M3

SCREW

6.2

(.24)

BUS A

INTERNAL POWER

*

BUS B

*

For dual redundant communication.

BUS CONNECTOR

1

18

Do 1

Do 16

17

Do 15

16

Do 14

15

Do 13

14

Do 12

13

Do 11

12

Do 10

11

Do 9

8

Do 8

7

Do 7

6

Do 6

5

Do 5

4

Do 4

3

Do 3

2

Do 2

1

19

9

10

20

24V DC

L

L

L

L

L

L

L

L

24V DC

24V DC

L

L

L

L

L

L

L

L

COM

COM

 DIMENSIONS  mm (inch)

 CONNECTION DIAGRAM

TERMINAL CONNECTIONS

Connect the unit as in the diagram below.

Summary of Contents for R3-PD16A

Page 1: ...e hot inser tion removal ia used as initial value For the combina tion with non cyclic Modbus communication modules R3 NM1 R3 NE1 etc write the output data immediately before the hot insertion removal...

Page 2: ...put Hold SW3 Effective only in continuance output mode SW OUTPUT HOLD HOLD OFF SW3 1 OFF ON Factory setting Configuration SW3 SW MODE SW3 2 SW3 3 OFF OFF One Shot Output Mode ON OFF ON OFF Control Out...

Page 3: ...t For every setting ON time will be as indicated below SW ON TIME sec 0 1 0 2 0 3 0 4 0 5 25 5 25 6 SW1 1 OFF ON OFF ON OFF OFF ON SW1 2 OFF OFF ON ON OFF ON ON SW1 3 OFF OFF OFF OFF ON ON ON SW1 4 OF...

Page 4: ...hannel is Not Swapped SW2 8 OFF 1 Output data Do 1 changes from 0 to 1 2 After Do 1 s rising edge Ch1 s one shot output turns ON for a fixed period of time SW1 s time set 3 After one shot output compl...

Page 5: ...nges from 1 to 0 5 After Do 1 s sinking edge Ch1 s one shot output turns ON for a fixed period of time SW1 s time set 6 After one shot output completion Di 1 Ch1 output completed status changes from 0...

Page 6: ...Output Completion Status 0 Ch6 Output Completion Reset Do 7 1 Ch7 Output Di 7 Ch7 Output Completion Status 0 Ch7 Output Completion Reset Do 8 1 Ch8 Output Di 8 Ch8 Output Completion Status 0 Ch8 Outp...

Page 7: ...letion Status 1 1 Output Data Reset Do 9 Do 10 0 0 Not Operating 1 0 Ch9 Output Di 9 Ch9 Output Completion Status 0 1 Ch10 Output Di 10 Ch10 Output Completion Status 1 1 Output Data Reset Do 11 Do 12...

Page 8: ...is an example of Do1 Do WRITE ONE SHOT OUTPUT RESET Di OUTPUT COMPLETION STATUS Do 1 0 Ch2 Output Di 2 Ch2 Output Completion Status 1 Ch1 Output Di 1 Ch1 Output Completion Status CONTINUANCE OUTPUT MO...

Page 9: ...IGNMENT Do Note For 8 bit length ON OFF control mode Do 9 through Do 16 are unavailable Di Note Di data is not practical discrete input data It is output completion status internal data 0 15 Di 1 Di 2...

Page 10: ...WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE M SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamit...

Reviews: