background image

R3-PD16A

P. 6 / 10

EM-8397 Rev.1

 ONE-SHOT OUTPUT MODE

16-bit output data (Do 1 through 16) and output (Ch1 through 16) are assigned 1:1.

When I/O Mode is in Output Operation (SW2-7: ON), Output Complete Status is not indicated.

Do

WRITE

ONE-SHOT OUTPUT/RESET

Di

OUTPUT COMPLETION STATUS

Do 1

1

Ch1 Output

Di 1

Ch1 Output Completion Status

0

Ch1 Output Completion Reset

Do 2

1

Ch2 Output

Di 2

Ch2 Output Completion Status

0

Ch2 Output Completion Reset

Do 3

1

Ch3 Output

Di 3

Ch3 Output Completion Status

0

Ch3 Output Completion Reset

Do 4

1

Ch4 Output

Di 4

Ch4 Output Completion Status

0

Ch4 Output Completion Reset

Do 5

1

Ch5 Output

Di 5

Ch5 Output Completion Status

0

Ch5 Output Completion Reset

Do 6

1

Ch6 Output

Di 6

Ch6 Output Completion Status

0

Ch6 Output Completion Reset

Do 7

1

Ch7 Output

Di 7

Ch7 Output Completion Status

0

Ch7 Output Completion Reset

Do 8

1

Ch8 Output

Di 8

Ch8 Output Completion Status

0

Ch8 Output Completion Reset

Do 9

1

Ch9 Output

Di 9

Ch9 Output Completion Status

0

Ch9 Output Completion Reset

Do 10

1

Ch10 Output

Di 10

Ch10 Output Completion Status

0

Ch10 Output Completion Reset

Do 11

1

Ch11 Output

Di 11

Ch11 Output Completion Status

0

Ch11 Output Completion Reset

Do 12

1

Ch12 Output

Di 12

Ch12 Output Completion Status

0

Ch12 Output Completion Reset

Do 13

1

Ch13 Output

Di 13

Ch13 Output Completion Status

0

Ch13 Output Completion Reset

Do 14

1

Ch14 Output

Di 14

Ch14 Output Completion Status

0

Ch14 Output Completion Reset

Do 15

1

Ch15 Output

Di 15

Ch15 Output Completion Status

0

Ch15 Output Completion Reset

Do 16

1

Ch16 Output

Di 16

Ch16 Output Completion Status

0

Ch16 Output Completion Reset

Summary of Contents for R3-PD16A

Page 1: ...e hot inser tion removal ia used as initial value For the combina tion with non cyclic Modbus communication modules R3 NM1 R3 NE1 etc write the output data immediately before the hot insertion removal...

Page 2: ...put Hold SW3 Effective only in continuance output mode SW OUTPUT HOLD HOLD OFF SW3 1 OFF ON Factory setting Configuration SW3 SW MODE SW3 2 SW3 3 OFF OFF One Shot Output Mode ON OFF ON OFF Control Out...

Page 3: ...t For every setting ON time will be as indicated below SW ON TIME sec 0 1 0 2 0 3 0 4 0 5 25 5 25 6 SW1 1 OFF ON OFF ON OFF OFF ON SW1 2 OFF OFF ON ON OFF ON ON SW1 3 OFF OFF OFF OFF ON ON ON SW1 4 OF...

Page 4: ...hannel is Not Swapped SW2 8 OFF 1 Output data Do 1 changes from 0 to 1 2 After Do 1 s rising edge Ch1 s one shot output turns ON for a fixed period of time SW1 s time set 3 After one shot output compl...

Page 5: ...nges from 1 to 0 5 After Do 1 s sinking edge Ch1 s one shot output turns ON for a fixed period of time SW1 s time set 6 After one shot output completion Di 1 Ch1 output completed status changes from 0...

Page 6: ...Output Completion Status 0 Ch6 Output Completion Reset Do 7 1 Ch7 Output Di 7 Ch7 Output Completion Status 0 Ch7 Output Completion Reset Do 8 1 Ch8 Output Di 8 Ch8 Output Completion Status 0 Ch8 Outp...

Page 7: ...letion Status 1 1 Output Data Reset Do 9 Do 10 0 0 Not Operating 1 0 Ch9 Output Di 9 Ch9 Output Completion Status 0 1 Ch10 Output Di 10 Ch10 Output Completion Status 1 1 Output Data Reset Do 11 Do 12...

Page 8: ...is an example of Do1 Do WRITE ONE SHOT OUTPUT RESET Di OUTPUT COMPLETION STATUS Do 1 0 Ch2 Output Di 2 Ch2 Output Completion Status 1 Ch1 Output Di 1 Ch1 Output Completion Status CONTINUANCE OUTPUT MO...

Page 9: ...IGNMENT Do Note For 8 bit length ON OFF control mode Do 9 through Do 16 are unavailable Di Note Di data is not practical discrete input data It is output completion status internal data 0 15 Di 1 Di 2...

Page 10: ...WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE M SYSTEM SHALL HAVE NO LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES OF ANY KIND WHATSOEVER M System Co Ltd 5 2 55 Minamit...

Reviews: