Address(ID)
Selection Switches
Selection Switches
Protocol
Selection Switches
Termination,Full Up/Down
SW2
S4
S3
S1
S2
H
eat
er AC
24
V~
1 Au
x O
u
tp
ut
4 Al
arm In
put
Vi
deo
Power A
C
24V~
Com
m
.(
R
X
/T
X
)
Fan & Heater
Figure 3 – Layout of Switches
2.3
Principle of Termination
Every device that is connected at the end of the communication data line must
be terminated by either the DIP switch setting or an appropriate device such as
a termination jumper to prevent potential control signal errors.
See Figure 4 for termination switch settings and Figure 5 for examples of devices
requiring termination. Note: Total length of the cable for communication should
not exceed 1.2Km or .74 mile.
Figure 4– Setting Dome Camera Termination
** Unless communication error, put the position 2, 3 of the SW2 in OFF state.
Position 2, 3 should be set as a pair. (Both 2, 3 to ON position or OFF position)
SW2 1
2
3
Terminated ON X X
Not terminated
OFF
X
X
Full Up/Down **
X
ON
ON
Normal **
X
OFF
OFF
SW2
ON
12
3