background image

Flame Quality Adjustment

 
 
 
 

WARNING:

 

Incorrect adjustment of flame can lead to improper combustion which can be a safety hazard.

 

Thermopile

Pilot Flame

Igniter Electrode

Thermocouple

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Flame Types

Adjustment

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

 

 

 

 

1.  Blue at the base with 

active light orange.  
Medium height (ideal) 

 
 
 
 
2.  All blue with little or no 

orange.  Short height (too 
much air) 

 
 

 
 

 
3.  Lazy yellow with little or 

no blue.  Long stringy 
flame (no air) May result 
in sooty deposits on glass 

 

 

 
 
None 
 
 
 
 
 
 
Close damper  
 
 
 
 
 
 
 
Open damper

 

Pilot Check:

 

The MBO-36 utilizes a standing pilot which remains on at all times. Pilot assembly is 

covered almost entirely by the wind shield and maybe difficult to see. The visible part of the flame tips 
should always be blue in colour. If the flame characteristics are in doubt a qualified technician or gas 
installer can remove the wind shield and make any adjustments if required. 

 

 

16

Summary of Contents for MBO-36

Page 1: ...ure reference Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not tou...

Page 2: ...nces it maybe installed unsheltered and exposed directly to many weather conditions Avoid any prolonged heavy rain exposure directly into the firebox Use the optional cover when extended shutdown peri...

Page 3: ...d have at least on fire extinguisher An approved Class A B C extinguisher should be mounted on the wall near an exit and close to the application but not so close that accessibility to the extinguishe...

Page 4: ...l codes with the National Fuel Gas and Propane Installation Code ANSI Z223 1 NFPA 54 in the US or the Natural Gas and Propane Installation Code CSA B149 1 in Canada Please contact Canadian Fire Hearth...

Page 5: ...000 BTU hr High altitude US 0 2000ft 0 610m High altitude Canada 0 4500ft 0 1370m Primary Air Opening Vent System Ventless Clean Face Kit factory installed on all units 304 Stainless Steel Please Note...

Page 6: ...arances to air conditioning ducts electrical wiring and plumbing Safety as well as efficiency of operation must be considered in selecting a fireplace location Select a location that does not interfer...

Page 7: ...must not be covered Doing so will prevent proper water drainage The tray can be pulled out to match the thickness of any desired material Sliding drain tray Mantel Requirements Top edge of fireplace o...

Page 8: ...gnated areas PLEASE NOTE It is mandatory that all supplied non combustible panels be installed Failure to do so could result in damage to adjacent materials and or fire 3 82 1 70 Combustible Enclosure...

Page 9: ...nce to the gas supply line double check that the appliance you have purchased is designed for the gas type you are using The gas type markings are located on the certification label and also on the ap...

Page 10: ...ireplace shall not open directly above a sidewalk or paved 3 All gravity air intakes within 3 ft of the fireplace must be driveway which is located between two single family dwellings a minimum of 1 f...

Page 11: ...ve on this label 2 Set the thermostat to lowest setting 3 Turn off all electrical power to the appliance 4 Remove louvers 5 Push in gas control knob slightly and turn clockwise to OFF Note knob cannot...

Page 12: ...is imperative that control compartment covers of the appliance to be kept clean Pressure testing the supply line for leaks The appliance and its individual shut off valve must be disconnected from the...

Page 13: ...e air inlet A small tab folded up from the shelf is provided to secure to log in position Push the logs down onto the shelf so that the tab forces into the logs Use sufficient force only to push the t...

Page 14: ...into the corresponding hole as shown in the insert Support the lower end of the angled logs on the brace mounted on the burner face as shown Place log 4 onto the logs set in the previous step Use the...

Page 15: ...on below NOTE It is important that while placing the logs and stones they must not directly cover any of the burner ports If the outdoor installation will be subjected to much greater than normal wind...

Page 16: ...ch air 3 Lazy yellow with little or no blue Long stringy flame no air May result in sooty deposits on glass None Close damper Open damper Pilot Check The MBO 36 utilizes a standing pilot which remains...

Page 17: ...Gasket GK01 CFH Electronic Pilot Assembly DC006E Main Burner Orifice Natural Gas MBO36NG Replacement Log Set LSMBO36 NON COMBUSTABILE COMPONENTS Top Panel placed on top edge of Cleanface Surround 40 x...

Page 18: ...liquids Log set burner require no maintenance Cold Weather Operation When using any gas appliance LP or NG Fuels water is a byproduct of the combustion process Under normal conditions this is expelle...

Page 19: ...ime Warranty CFHMfg may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defect...