Thermostat Installation (not allowed in US installations) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

wall switch installation

The burner control switch is located in the centre of the control department opening.  For your convenience, the unit can 
also be operated by a thermostat or a wall switch control.  Electronic are available from any authorized CFHMfg dealer.  
Please note, bedroom installations require the use of a wall thermostat.  Mount the thermostat or switch in the desired 
location and run “two conductor thermostat wires” to the heater’s lower right hand corner, close to the gas supply line. 

Note: The wall switch MUST  be rated for electronic 

1.6 

 100 

 30.5 

 

14 

Minimize splicing in all wiring and solder all unavoidable splices. 

 

Thermostat Wire Information 

 

AWG 

 mm 

 ft. 

 m 

22 

 0.6 

 10 

 3.0 

20 

 0.8 

 25 

 7.6 

18 

 1.0 

 40 

 12.2 

16 

 1.3 

 64 

 19.5 

 
 
 
 
 
 
 

For maintenance, proper re-assembly and resealing of the venting system is required. 
The appliance should be inspected before use and at least annually by a professional service 
person. 

More frequent cleaning may be required due to excessive lint from carpet bedding material etc.  It is imperative 
that control compartment, covers of the appliance to be kept clean. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Pressure testing the supply line for leaks 

 

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure 
testing of the system at test pressures in excess of ½ psig (3.4kPa).  The appliance must be isolated from the gas supply piping 
system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psig (3.5kPa).  Failure to do so will damage the appliance’s gas valve.  Such damage is not 
covered by the manufacturer’s warranty. 
 
When testing for leaks: 
Make sure that the appliance is turned off. 
Open the manual shut-off valve. 
Test for leaks by applying a liquid detergent or soap solution to all ball joints.  Bubbles forming indicate a gas leak. 
Correct any leak detected immediately. 

Never use an open flame to check for leaks. 

 

The pressure test point locations are built in to the regulator that controls the burner manifold pressure.  The correct pressure 
range is shown in the table in the specification section of this manual.  The pressure check should be made with the burner lit. 

See lighting instruction section for full operating details. 

 

 

12

Summary of Contents for MBO-36

Page 1: ...ure reference Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not tou...

Page 2: ...nces it maybe installed unsheltered and exposed directly to many weather conditions Avoid any prolonged heavy rain exposure directly into the firebox Use the optional cover when extended shutdown peri...

Page 3: ...d have at least on fire extinguisher An approved Class A B C extinguisher should be mounted on the wall near an exit and close to the application but not so close that accessibility to the extinguishe...

Page 4: ...l codes with the National Fuel Gas and Propane Installation Code ANSI Z223 1 NFPA 54 in the US or the Natural Gas and Propane Installation Code CSA B149 1 in Canada Please contact Canadian Fire Hearth...

Page 5: ...000 BTU hr High altitude US 0 2000ft 0 610m High altitude Canada 0 4500ft 0 1370m Primary Air Opening Vent System Ventless Clean Face Kit factory installed on all units 304 Stainless Steel Please Note...

Page 6: ...arances to air conditioning ducts electrical wiring and plumbing Safety as well as efficiency of operation must be considered in selecting a fireplace location Select a location that does not interfer...

Page 7: ...must not be covered Doing so will prevent proper water drainage The tray can be pulled out to match the thickness of any desired material Sliding drain tray Mantel Requirements Top edge of fireplace o...

Page 8: ...gnated areas PLEASE NOTE It is mandatory that all supplied non combustible panels be installed Failure to do so could result in damage to adjacent materials and or fire 3 82 1 70 Combustible Enclosure...

Page 9: ...nce to the gas supply line double check that the appliance you have purchased is designed for the gas type you are using The gas type markings are located on the certification label and also on the ap...

Page 10: ...ireplace shall not open directly above a sidewalk or paved 3 All gravity air intakes within 3 ft of the fireplace must be driveway which is located between two single family dwellings a minimum of 1 f...

Page 11: ...ve on this label 2 Set the thermostat to lowest setting 3 Turn off all electrical power to the appliance 4 Remove louvers 5 Push in gas control knob slightly and turn clockwise to OFF Note knob cannot...

Page 12: ...is imperative that control compartment covers of the appliance to be kept clean Pressure testing the supply line for leaks The appliance and its individual shut off valve must be disconnected from the...

Page 13: ...e air inlet A small tab folded up from the shelf is provided to secure to log in position Push the logs down onto the shelf so that the tab forces into the logs Use sufficient force only to push the t...

Page 14: ...into the corresponding hole as shown in the insert Support the lower end of the angled logs on the brace mounted on the burner face as shown Place log 4 onto the logs set in the previous step Use the...

Page 15: ...on below NOTE It is important that while placing the logs and stones they must not directly cover any of the burner ports If the outdoor installation will be subjected to much greater than normal wind...

Page 16: ...ch air 3 Lazy yellow with little or no blue Long stringy flame no air May result in sooty deposits on glass None Close damper Open damper Pilot Check The MBO 36 utilizes a standing pilot which remains...

Page 17: ...Gasket GK01 CFH Electronic Pilot Assembly DC006E Main Burner Orifice Natural Gas MBO36NG Replacement Log Set LSMBO36 NON COMBUSTABILE COMPONENTS Top Panel placed on top edge of Cleanface Surround 40 x...

Page 18: ...liquids Log set burner require no maintenance Cold Weather Operation When using any gas appliance LP or NG Fuels water is a byproduct of the combustion process Under normal conditions this is expelle...

Page 19: ...ime Warranty CFHMfg may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defect...

Reviews: