Installation Planning 

 
 
 
 
 
 
 
 
 
 

The recommended order of installation is as follows:

1 – Familiarize yourself with this manual. 
2 – Check the minimum installation dimensions. 
3 – Check your local installation codes. 
4 – Check you have the parts and components necessary to complete the installation. 
5 – Check the gas and electrical supplies are ready. 
6 – Prepare opening (remove any loose materials) 
7 – Install base unit.  
8 – Connect gas.  
9 – Install operational components and prepared for first test fire. 
10 – Check to verify adequate accessibility clearance for service & proper operation. 
11 – Check operation of unit. 
12 – Take time to explain operation to customer (most call backs are caused by the customer not understanding the operation     
of the unit.) 

 

 

 
 

 

Installing Gas and Electrical Supply Lines. 

 

Gas and lines must be installed and accessible for the installation of the MBO-36. 
Natural Gas requires a minimum inlet gas pressure of 5.5 in W.C.. 

IMPORTANT:

 Installer please allow a portion of 

the gas line connecting to the appliance to be flexible enough for moving and aligning the appliance into the 
chase.  

 
 
 
 
 
 

Existing Gas Supply

Before interrupting the existing gas supply it is recommended that the following be checked. 
Shut down all gas appliances and carry out a pressure test to ensure there are no leaks in the system. 
Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the 
gas type you are using.  The gas type markings are located on the certification label and also on the appliance’s gas valve. 
Check the gas pressure immediately upstream to ensure you will be able to supply the minimum inlet pressure for the 
appliance. 
Check your pipe sizing to ensure sufficient volume will be supplied to the appliance. 

 

 
 
 
 
 
 
 
 
 
 
 

Gas Supply Installation

Provide adequate clearance for the proper installation and checking of the gas connection. 
Have your gas supplier or a qualified gas fitter run a gas supply line into the gas fireplace.  The line must be properly sized and 
fitted according to the installation codes.  Upstream of the appliance supply connection, the fitter shall provide an easily 
accessible manual shut-off valve. 
The gas supply pipe should enter the appliance case through the opening at the right side.  The supply pipe should be 
connected to the appliance gas inlet pipe situated at the right side of the control unit.  Supply line connection to the inlet pipe is 
3/8 NPT. 
Use only new black iron or steel pipes or copper tubing if acceptable – check local codes. 
 

Note that in the USA copper tubing must be internally tinned for protection against sulfur compounds. 

Unions in gas should be of ground joint type.  Sealant used must be resistant to the action of all gas constituents including LP 
gas.  Sealant should be applied lightly to male threads to ensure excess sealant does not enter gas lines. 
 

 

 

9

Summary of Contents for MBO-36

Page 1: ...ure reference Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not tou...

Page 2: ...nces it maybe installed unsheltered and exposed directly to many weather conditions Avoid any prolonged heavy rain exposure directly into the firebox Use the optional cover when extended shutdown peri...

Page 3: ...d have at least on fire extinguisher An approved Class A B C extinguisher should be mounted on the wall near an exit and close to the application but not so close that accessibility to the extinguishe...

Page 4: ...l codes with the National Fuel Gas and Propane Installation Code ANSI Z223 1 NFPA 54 in the US or the Natural Gas and Propane Installation Code CSA B149 1 in Canada Please contact Canadian Fire Hearth...

Page 5: ...000 BTU hr High altitude US 0 2000ft 0 610m High altitude Canada 0 4500ft 0 1370m Primary Air Opening Vent System Ventless Clean Face Kit factory installed on all units 304 Stainless Steel Please Note...

Page 6: ...arances to air conditioning ducts electrical wiring and plumbing Safety as well as efficiency of operation must be considered in selecting a fireplace location Select a location that does not interfer...

Page 7: ...must not be covered Doing so will prevent proper water drainage The tray can be pulled out to match the thickness of any desired material Sliding drain tray Mantel Requirements Top edge of fireplace o...

Page 8: ...gnated areas PLEASE NOTE It is mandatory that all supplied non combustible panels be installed Failure to do so could result in damage to adjacent materials and or fire 3 82 1 70 Combustible Enclosure...

Page 9: ...nce to the gas supply line double check that the appliance you have purchased is designed for the gas type you are using The gas type markings are located on the certification label and also on the ap...

Page 10: ...ireplace shall not open directly above a sidewalk or paved 3 All gravity air intakes within 3 ft of the fireplace must be driveway which is located between two single family dwellings a minimum of 1 f...

Page 11: ...ve on this label 2 Set the thermostat to lowest setting 3 Turn off all electrical power to the appliance 4 Remove louvers 5 Push in gas control knob slightly and turn clockwise to OFF Note knob cannot...

Page 12: ...is imperative that control compartment covers of the appliance to be kept clean Pressure testing the supply line for leaks The appliance and its individual shut off valve must be disconnected from the...

Page 13: ...e air inlet A small tab folded up from the shelf is provided to secure to log in position Push the logs down onto the shelf so that the tab forces into the logs Use sufficient force only to push the t...

Page 14: ...into the corresponding hole as shown in the insert Support the lower end of the angled logs on the brace mounted on the burner face as shown Place log 4 onto the logs set in the previous step Use the...

Page 15: ...on below NOTE It is important that while placing the logs and stones they must not directly cover any of the burner ports If the outdoor installation will be subjected to much greater than normal wind...

Page 16: ...ch air 3 Lazy yellow with little or no blue Long stringy flame no air May result in sooty deposits on glass None Close damper Open damper Pilot Check The MBO 36 utilizes a standing pilot which remains...

Page 17: ...Gasket GK01 CFH Electronic Pilot Assembly DC006E Main Burner Orifice Natural Gas MBO36NG Replacement Log Set LSMBO36 NON COMBUSTABILE COMPONENTS Top Panel placed on top edge of Cleanface Surround 40 x...

Page 18: ...liquids Log set burner require no maintenance Cold Weather Operation When using any gas appliance LP or NG Fuels water is a byproduct of the combustion process Under normal conditions this is expelle...

Page 19: ...ime Warranty CFHMfg may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defect...