Hydraulic installations
19
© Lutz-Jesco GmbH 2020
Subject to technical changes.
200318
BA-10491-02-V01
Piston diaphragm dosing pump
MEMDOS KMS LB/LA
Operating instructions
8 Hydraulic installations
In this chapter, you will find information about the hydraulic parts of a
system that you should install or that can install additionally. In many cas-
es, you must install hydraulic accessories to be able to guarantee func-
tional safety or to achieve a high level of dosing precision.
WARNING
Caustic burns or other burns through dosing media!
A diaphragm rupture, blocked pressure lines or the use of material not
suitable for the dosing medium can result in the discharge of dosing
medium. Depending on the type and hazardousness of the dosing me-
dium, this can result in injury.
ð
Wear the recommended personal protective equipment.
ð
Make sure that the materials you are using are suitable for the dos-
ing medium.
ð
Make sure that the lubricants, adhesives, sealants, etc. that you use
are suitable for the dosing medium.
ð
Install a leakage drain.
ð
Install pressure relief valves.
CAUTION!
Danger of personal injury and material damage!
High peak pressures can lead to piping vibrating and cause them to
snap. This can result in injury from piping or escaping dosing media.
ð
Install pulsation dampeners.
PLEASE NOTE
Damage to drives due to overloading
The pressure conditions between the suction and discharge sides must
be balanced; otherwise, overloading can result. This can lead to uncon-
trolled dosing processes and damage to the piping as well as to the
dosing pump.
ð
Ensure that the pressure on the discharge side is at least 1 bar than
on the suction side.
PLEASE NOTE
Locking of threads
Stainless steel and plastic parts (particularly those made of PVC) that
are bolted together in a detachable connection (e.g. the dosing head
and the valves) can lock. This makes them difficult to release.
ð
Before bolting, grease the corresponding parts with a lubricant (e.g.
PTFE spray). Ensure that the lubricant is compatible with the dosing
medium.
Warning notice for installation in an explosive risk zone:
DANGER!
Danger to life through explosions!
Systems without a pressure relief valve fitted produce an increased
safety risk in an explosive risk zone. Explosions could occur if system
parts heat up during an overload or by sparks which may be created if
drive parts were to break.
ð
Install a pressure relief valve on the pressure side of the dosing
pump.
8.1 Design of the system
n
The dosing pumps technical data (see chapter 5 „Technical data“ on
page 13) must be taken into account and the plant s layout must
be set up appropriately (e.g. pressure loss when rating the lines with
regard to their nominal diameter and length).
n
The entire system and its integrated dosing pump must be designed
in such a way that an escaping dosing medium (due to the failure of
wearing parts such as the diaphragm, or burst hoses) does not lead to
permanent damage to system parts or the premises.
n
If you use hazardous dosing media, the installation must be designed
such that no disproportionately high consequential damages arise
due to dosing media escaping.
n
To avoid dosing errors after the end of the process, the dosing pump
must be locked hydraulically.
n
To allow you to easily inspect the pressure conditions in the system,
you should provide connections for pressure gauges close to the suc-
tion and pressure valves.