Technical data
9
© Lutz-Jesco GmbH 2018
Subject to technical changes
180321
BA-24721-02-V02
Chlorine gas changeover unit
C 7523
Operating instructions
5 Technical data
Description
Value
Throughput
up to 80 kg/h Cl
2
Operating pressure
-1…0 bar
Contact gauge
Ø63 mm, -1…0 bar
Setting range of the switching point on the contact gauge
-0.9…-0.1 bar
Changeover time
approx. 22 s
Material in contact with the media
PVC / FPM / Silver / coated brass
Further materials
Coated steel, PP, ABS
Voltage supply
115/230 V, 50/60 Hz
Power consumption
Normal mode
max. 0.3 A
Switch-on current
max. 17.5 A (peak)
Load capacity of the relay
max. 3 A / 250 V AC
Weight
Without mounting plate
approx. 5 kg
With mounting plate
approx. 7 kg
Protection class
IP 65
Ambient temperature
0 – 55 °C, avoid direct sunlight
Air humidity
max. 95%, non condensing
Table 6: Technical data
Product
Hydraulic connections
Max. flow rate
C7523-4K
Hose 8/12 mm
4 kg/h Cl
2
C7523-10K
Hose 12/16 mm
10 kg/h Cl
2
C7523-40K
Pipe DN25/Ø32
40 kg/h Cl
2
C7523-80K
Pipe DN32/Ø40
80 kg/h Cl
2
Table 7: Maximum flow