CDD3000-HF Operation Manual
3-11
3 Installation
DE
EN
FR
IT
ES
FR
Pin assignment
You can enter your custom assignment in the columns for connector B.
Technical data of LUST encoder cables
These cables are supplied ready made-up in various lengths.
Connec-
tor A
Function
Sine/cosine
SSI
function
HIPERFACE
®
function
Connec-
tor B
Wire
colour
CDD3000-
HF X7
Custom
1
A-
A-
REFCOS
2
A+
A+
+COS
3
+5 V / 150 mA
+5 V / 150 mA
4
DATA+
Data+ RS485
5
DATA-
Data- RS485
6
B-
B-
REFSIN
7
Us 7-12V /
100mA*
8
GND
GND
GND
9
R-
10
R+
11
B+
B+
+SIN
12
+5 V / (sensor)
+5 V / (sensor)
13
GND (sensor)
GND (sensor)
14
CLK+
15
CLK-
Outer and inner shield (if fitted) on both sides of housing
* To 250 mA with ex24 V (-5 %/+20 %) supply via terminal X2 permitted.
Table 3.5
Encoder cable pin assignment
KRY-KSxxx
1)
KGN-KSxxx
1)
KGS-KSxxx
1)
KGH-KSxxx
1)
drive controller type
CDD3000-HF
Motors with encoder system
R1, R2, R8,
K1, K2, K8
G1
G2, G3, G5
G6, G7
Festoon-compatible
yes
Table 3.6
Technical data of LUST encoder cables