5-6
CDD3000-HF Operation Manual
5 Diagnosis/Fault rectification
5.8
Reset
Parameter reset
In PARA menu of K
EY
P
AD
:
Press the two cursor keys to reset the parameter currently being edited to
the factory defaults.
In the D
RIVE
M
ANAGER
:
In the focused setup window by pressing the F1 key. The factory setting of
the parameter is indicated on the “Value range” tab and is to be entered
there.
Factory setting
K
EY
P
AD
:
Press both K
EY
P
AD
cursor keys simultaneously during CDD3000-HF
power-up to reset all parameters to their factory defaults and the system
is reinitialized.
D
RIVE
M
ANAGER
:
Select the “Reset to factory setting” function from the “Active Device”
menu.
Note:
Attention! Resetting the factory defaults will delete the motor
data settings and the preset solution “SCT_2-Speed control,
±10 V reference, controlled via terminal” will be loaded. Pay
attention to the terminal assignment and the functionality of
the CDD3000-HF in this preset solution.