CDD3000-HF Operation Manual
3-19
3 Installation
DE
EN
FR
IT
ES
FR
1) Functional isolation between digital (DGND) and analog (AGND) ground. For more information see section
15
OSD01
•
Short-circuit-proof
•
PLC-compatible, sampling time 1 ms
•
I
max
= 50 mA, high-side driver
•
Protection against inductive load
✓
Relay
output
16
17
OSD02
•
Relay, 1 NO contact
•
25 V / 0,25 A AC, usage category AC1
•
30 V / 0,25 A DC, usage category DC1
•
Sampling time 1 ms
•
Operating delay approx. 10 ms
✓
Voltage
supply
5
6, 13
+24 V
DGND
1)
•
Auxiliary voltage U
V
= 24 V DC, short-circuit-
proof
•
Tolerance: +20%
•
I
max
= 100 mA (overall, also includes driver
currents for outputs OSD0x)
•
External 24V supply to control electronics in
case of power failure possible,
current consumption I
max
= 1 A
✓
Motor
holding
brake
18
19
20
VCC03
GND03
OSD03
•
D24 V output, high-active
•
Short-circuit-proof
•
Suitable for actuation of a motor holding
brake (specification, see section 3.3.3)
•
I
max
= 2.0 A (current overload causes
shut-off) to
υ
Umax
=45°C; reduction of I
max
at
υ
U
> 45°C.
•
I
min
= 150 mA (I < I
min
wire break causes
shut-off)
•
Separate voltage supply required:
U
IN
= + 24 V ± 10%
I
IN
= 2.1 A
•
Also usable as configurable digital output
✓
No.
Des.
Specification
Isolation