Lundix It SPC Bridge KNX User Manual Download Page 22

 

 

© PROPERTY OF LUNDIX IT SWEDEN, ALL RIGHTS RESERVED – THIS DOCUMENT AND THE INFORMATION CONTAINED THEREIN ARE CONFIDENTIAL – THE DISCLOSURE OR OTHER COMMUNICATION, COPYING, REPRODUCTION 
AND ANY USE WHATSOEVER IS FORBIDDEN WITHOUT THE WRITTEN AUTHORIZATION OF LUNDIX IT. 

 

SPC Bridge KNX User Manual 

Revision 

1.0 

Page 

22 of 25 

Reference 

2020-111 

7

 

Appendices 

7.1

 

SPC Command Error Codes 

Error Code 
 

Error Message 

OK: Command succeeded 

10  

ERROR: Generic  

11  

ERROR: Unknown  

12  

ERROR: Missing ID  

13  

ERROR: Invalid ID  

14  

ERROR: Unknown Tag  

15  

ERROR: Memory Full  

16  

ERROR: Invalid Data  

17  

ERROR: Missing Data  

18  

ERROR: Invalid CRC  

19  

ERROR: Invalid Length  

20  

ERROR: Not ready  

21  

ERROR: Invalid Sequence No  

22  

ERROR: Invalid Decryption  

23  

ERROR: Invalid Connection Details  

24  

ERROR: Invalid Username  

25  

ERROR: Invalid Password  

40  

ERROR: Generic check failed  

50  

ERROR: Active  

51  

ERROR: Inactive  

52  

ERROR: Invalid User  

53  

ERROR: Invalid Number  

54  

ERROR: Authentication Failed  

55  

ERROR: Engineer Not Authorizedl  

56  

ERROR: Invalid Name  

57  

ERROR: Invalid Profile  

58  

ERROR: Invalid Site Code  

59  

ERROR: Invalid PIN  

60  

ERROR: Duplicate  

61  

ERROR: Invalid Card Number  

62  

ERROR: In use  

63  

ERROR: Global ID in use  

64  

ERROR: Global Data Protected  

65  

ERROR: No Rights  

66  

ERROR: System Set  

67  

ERROR: Cannot delete  

68  

ERROR: Cannot delete last  

69  

ERROR: Date  

70  

ERROR: Calendar  

71  

ERROR: Area  

72  

ERROR: Door  

73  

ERROR: Web password not enabled  

Summary of Contents for SPC Bridge KNX

Page 1: ...SPC Bridge KNX User Manual Revision 1 0...

Page 2: ...MUNICATION COPYING REPRODUCTION AND ANY USE WHATSOEVER IS FORBIDDEN WITHOUT THE WRITTEN AUTHORIZATION OF LUNDIX IT SPC Bridge KNX User Manual Revision 1 0 Page 2 of 25 Reference 2020 111 History Recor...

Page 3: ...9 3 3 Time Setting 9 3 4 Change Administration Password 9 4 SPC BRIDGE CONFIGURATION 10 4 1 SPC Bridge Sign In 10 4 2 SPC Communication FlexC 10 4 2 1 SPC Panel FlexC Settings 10 4 2 2 SPC Bridge SPC...

Page 4: ...OTHER COMMUNICATION COPYING REPRODUCTION AND ANY USE WHATSOEVER IS FORBIDDEN WITHOUT THE WRITTEN AUTHORIZATION OF LUNDIX IT SPC Bridge KNX User Manual Revision 1 0 Page 4 of 25 Reference 2020 111 7 1...

Page 5: ...m SPC Bridge KNX includes a certified Weinzierl KNX interface 332 or 312 for a reliable and approved connection to the KNX bus 1 2 Main Features Mirrors SPC zone and area states status to KNX bus Supp...

Page 6: ...um TP Interface protocol HID xEMI APDU length 55 Object Server BAOS V2 Device model System B Power supply USB 10 mA KNX 3 mA Connectors KNX via pluggable screw terminal USB connector type A Compatibil...

Page 7: ...12 to the SPC Bridge USB port 3 Connect the KNX bus cable to the KNX bus connector on the KNX interface NOTE The default individual device address of the KNX interface is 15 15 255 If this address alr...

Page 8: ...penWrt that is very common on routers The System Administration Web GUI contains many settings intended only for advanced users Only the settings described in this section should be changed by normal...

Page 9: ...servers 5 In DHCP Server General Setup check the checkbox Ignore interface NOTE It is very important to disable the DHCP server in the SPC Bridge to avoid conflict with your normal DHCP server 6 Click...

Page 10: ...nel FlexC Settings Use Vanderbilt SPC Web interface and define the FlexC communication following this instructions 1 Select Full Engineer mode 2 Create a specific user for the SPC Bridge communication...

Page 11: ...and change following from the default settings Encryption Key Mode Fixed Encryption Encryption key 64 hex digits Your own key Must be exactly 64 hex digits 0 9 a f 7 Leave Full Engineer mode 4 2 2 SP...

Page 12: ...in SPC Panel FlexC settings SPC Username and Password Credentials for FlexC communication User must be defined in the SPC Panel and have a corresponding web password NOTE Of security reason a saved p...

Page 13: ...Bus State Shows state of the KNX connection Online or Offline Manufacturer KNX interface manufacturer Serial Number KNX interface serial number Protocol Version KNC interface protocol version Configur...

Page 14: ...mmands Element Description Hide unused datapoints If this is checked only datapoints that have been accessed from SPC side is shown Datapoint Datapoint address Description Datapoint description DPT KN...

Page 15: ...NICATION COPYING REPRODUCTION AND ANY USE WHATSOEVER IS FORBIDDEN WITHOUT THE WRITTEN AUTHORIZATION OF LUNDIX IT SPC Bridge KNX User Manual Revision 1 0 Page 15 of 25 Reference 2020 111 4 8 System Use...

Page 16: ...templates 1 On ETS project page import the template project file that best match your size of SPC system 2 Open the template project In the Topology tree select and copy the item 1 1 1 SPC KNX SPC Bri...

Page 17: ...ion datapoint values are not reliable 1 SPC communication is OK 2 SPC communication has failed datapoint values are not reliable To test SPC communication please see section 4 3 DPT 5 1 byte CR T 10 S...

Page 18: ...diately The success error of the command is reported in Area command reply status The fail to set reason is reported in Area fail to set reason DPT 5 1 byte C W 15 Area delayed fullset command ID of a...

Page 19: ...lues Datapoint Type Length Flags 1 Area X unset 0 Area is not unset 1 Area is unset disarmed DPT 1 1 bit CR T 2 Area X partset A 0 Area is not partset A 1 Area is partset A DPT 1 1 bit CR T 3 Area X p...

Page 20: ...ert was preventing area fullset 200 0xC8 Other reason was preventing area fullset Will be sent to KNX bus every time Area mode changes to new value and if value changes of other reason e g at exit del...

Page 21: ...inistration GUI go to System Backup Flash firmware 3 Just to be sure do a backup copy of your settings with Download backup 4 Under Flash new firmware image Check Keep settings if you would like to pr...

Page 22: ...18 ERROR Invalid CRC 19 ERROR Invalid Length 20 ERROR Not ready 21 ERROR Invalid Sequence No 22 ERROR Invalid Decryption 23 ERROR Invalid Connection Details 24 ERROR Invalid Username 25 ERROR Invalid...

Page 23: ...nd 76 ERROR Pin Expired 77 ERROR Blocked 78 ERROR Not allowed in Engineer mode 79 ERROR Cannot delete default profile 80 ERROR Cannot edit default profile 100 ERROR XML Buffer Fail 101 ERROR XML Bad F...

Page 24: ...s You may make copies of the software as may be necessary for backup and archival purposes DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS Maintenance of Copyright Notices You must not remove or alter any...

Page 25: ...cense GPL and GNU Lesser General Public License LGPL version 2 These firmware images contain software licensed under the GPLv2 A copy of that license can be found at http www gnu org licenses gpl 2 0...

Reviews: