FILLING AND START-UP INSTRUCTIONS (continue)
STEP 2: START UP
Please review the following procedures and power-up procedures before supplying power:
I – Connection
1.
Check the voltage at the main power panel to be sure you have the correct voltage for the POWER SYSTEM being used. Also,
be sure the voltage is or – 10% of the mean voltage. For 120 VAC it should be between 108 VAC and 132 VAC.
2.
Test and reset the GFCI. If it does not operate properly, do not apply voltage to the Power System until the problem has been
corrected.
II – Initial Set-Up
1.
Apply power by turning on your dedicated GFCI circuit breaker (120 VAC).
2.
When your spa is initially powered up, it will go into priming mode, indicated by PR on the display panel. During priming
mode press JET button repeatedly (10-15 times) and make sure all air is exhausted from the pump. The Priming Mode will take less
than 5 minutes and then the spa will begin to heat.
3.
Make sure the jets are all wide open.
4.
Press the JET button on the topside control panel to activate the spa. Rotate the air control valves to “Max” and observe the increased
jet action.
5.
While the pump is running, check again for water leaks at the drain joints, or fittings in the equipment compartment. If
water is leaking from one of these areas, there is no need to call for service, refer to Troubleshooting Tips to learn how to
tighten the fitting. If assistance is required, your dealer or maintenance service may charge a small fee.
6.
Once you are sure your spa has no leaks, adjust the temperature control to the desired level and turn off the high-speed pump.