N32O
User's manual
50
11
Reset the counters of the main and the additional input. The
counters are reset if the input changes from inactive to
active (control by edge).
4018
0…65535
10
Minimum duration in milliseconds of the low level on the input no. 3
before it is considered as the low level.
4019
0…65535
10
Minimum duration in milliseconds of the low high on the input no. 3
before it is considered as the high level.
4020
0...11
0
The function of the binary input no. 4. Setting range as the binary input
3 function (register 4017).
4021
0...65535
10
Minimum duration in milliseconds of the low level on the input no. 4
before it is considered as the low level.
4022
0...65535
10
Minimum duration in milliseconds of the low high on the input no. 4
before it is considered as the high level.
4023
0...4
1
Selection of the value displayed on the main display field - measuring
value at the main input
Value
Description
0
Value directly measured, not converted by the individual
characteristic and the mathematical functions, without
averaging using the moving window method.
1
Measuring value averaged using the moving window
method and converted based on the selected mathematical
function and the individual characteristics.
2
Value additionally measured during the measurement of the
main value selected according to the configuration of the
main input type (e.g. a frequency in the period
measurement).
3
Minimum value of the measuring quantity, averaged and
converted using the mathematical functions and the
individual characteristic, occurring during the averaging
window.
4
Maximum value of the measuring quantity, averaged and
converted using the mathematical functions and the
individual characteristic, occurring during the averaging
window.
4024
0...6
6
Displayed precision - position of the decimal point.
0
000000
1
00000.0
2
0000.00
3
000.000
4
00.0000
5
0.00000
6
Automatic - the position of the decimal point is set for
maximum resolution.
4025
0..8
0
Contents of the bottom line of the display
Value
Description
0
Unit according to the selected unit (register 4026)
1
Measuring value on the main input, without the
mathematical operations and the individual characteristic,
not averaged.
2
Measuring value on the main input averaged using the
moving window method and converted based on the
selected mathematical function and the individual
characteristics.