N32O
User's manual
23
tIME
– current RTC time in hh.mmss format.
Note:
The averaging period is defined by
MAVG
setting.
Displayed (measured) value for which the
analog output will have a rated minimum value,
in accordance with the programmed output
type.
Default: 0
-99999…999999
Displayed (measured) value for which the
analog output will have a rated maximum
value, in accordance with the programmed
output type.
Default: 100
-99999…999999
Value of the signal on the analog output for
output value manual control.
Note: The value is set on the analog output
after detecting an error on the measuring input.
The maximum possible signal will be
generated if the value exceeds the maximum
value for a given output type.
Default: 0
0…22
Table 8
Parameter
symbol
Description
Range of changes
Setting the current time. Confirmation of the time
resets the seconds counter.
Default: (not applicable)
00:2359
Setting the current date in YYYY.MM.DD format,
where:
YY – year.
MM – month.
DD – day of the month.
Default: (not applicable)
00.01.01...99.12.31
Automatic change of DST and inversely
Default: OFF
OFF
– automatic time change disabled.
ON
– automatic time change enabled.
Password to access the meter configuration. When
the set value is different from zero, each attempt to
enter the menu of the meter will require entering a
password. In case of providing an incorrect
password, it will be possible to enter the menu in the
monitoring mode without a possibility of make any
changes.
Default: 0
0…9999
Restore default settings. Selecting YES setting will
restore all settings to the default settings and set
FACt setting to NO.
Default: NO
NO – do nothing.
YES – restore default settings (factory).
5.4 Meter functions
5.4.1
Measurement
The measuring inputs, main and additional inputs of the N32O meters can work in various
measuring modes. Certain functionalities for each type of the inputs are enabled, disabled,
or the purpose of a given setting changes, e.g. the filtering time for the fast counter mode
is expressed in microseconds, and for the slow counter mode in milliseconds. The table
below summarizes the availability of the functions depending on the selected measuring
mode.