Configuring Control Modules and System Timing
Configuring system clocking
Stinger® FS/Stinger FS+ Getting Started Guide
5-23
admin>
read ds3-atm { 1 trunk-module-1 2 }
DS3-ATM/{ shelf-1 trunk-module-1 2 } read
admin>
set line-config clock-source = eligible
admin>
set line-config clock-priority = low
admin>
write
DS3-ATM/{ shelf-1 trunk-module-1 2 } written
For another example, the following commands configure only the first port of the
second OC3-ATM trunk module as an eligible clock source. If this port becomes
unavailable and is not backed up, the unit begins using the built-in clock on the
primary control module.
admin>
read oc3-atm { 1 trunk-module-1 1 }
OC3-ATM/{ shelf-1 trunk-module-1 1 } read
admin>
set line-config clock-source = eligible
admin>
set line-config clock-priority = high
admin>
write
OC3-ATM/{ shelf-1 trunk-module-1 1 } written
Additional information about configuring OC3-ATM, DS3-ATM, and E3-ATM trunk
modules can be found in the
Stinger OC3-ATM Trunk Module Guide
, the
Stinger DS3-ATM
Trunk Module Guide
, and the
Stinger E3-ATM Trunk Module Guide
.