Preparing for the Installation
Preventing static discharge damage
Stinger® FS/Stinger FS+ Getting Started Guide
1-3
To minimize entanglement, right-handed people can wear the strap on the left hand.
Plug the other end of the wrist strap into the grounding jack provided on most Lucent
products, as shown in Figure 1-2.
Figure 1-2. Wrist strap plugged into a grounding jack
If a grounding jack is not available, use an alligator clip to connect the strap to
electrical ground.
Use the following two simple tests to verify that the wrist strap is functioning
properly:
■
Measure the resistance between the wrist strap and its grounding plug. Overall
resistance between these two points must be approximately 1 megohm. If it is
not, replace the strap.
■
Physically examine the strap for visible damage. If you see any damage, replace
the strap.
Remove plastics from your work area
Work areas must be kept clear of common plastics, such as the following items:
■
Polystyrene packing containers
■
Clear plastic bags
■
Plastic drinking cups
■
Food wrappers
■
Clear cellophane tape
These types of common plastic materials can carry a static charge that is not easily
discharged to ground and must not make direct contact with modules or any other
solid state components.