Configuring the Cajun P550 Switch (Layer 2 & Layer 3)
3
-
42
Cajun P550/P220 Switch Operation Guide
Installing Redundant Hardware
By default, the switch is configured without the redundant controller or element, as
shown in Figure 3-8.
Figure 3-8.
Default Hardware Configuration
To install the redundant modules and enable module redundancy:
1.
Shut down the switch.
WARNING:
Before replacing switch controllers or elements, turn off the switch.
2.
Install the redundant controller in the slot to the left of the primary controller. (Slot
1 in Figure 3-8).
Note:
Controllers and elements are equipped with keys to ensure that a controller
cannot be inserted into an element slot and an element cannot be inserted
into a controller slot.
3.
Install the redundant element in the slot to the left of the sixth element. (Slot 0 in
Figure 3-8).
4.
Restart the switch and login.
5.
In the
System Information
section of the Web Agent window, click
Switch
Fabric
. The Switch Fabric Status dialog box opens.
If the redundant controller and element installed properly, settings display as in
Figure 3-9.
Elements
6 - 4
Primary
Controller
Elements
3 - 1
Summary of Contents for Cajun P220
Page 1: ...Cajun P550 P220 Switch Operation Guide Version 4 0 ...
Page 3: ......
Page 20: ...Preface xxi Cajun P550 P220 Switch Operation Guide ...
Page 36: ...Cajun P550 Switch Overview 1 16 Cajun P550 P220 Switch Operation Guide ...
Page 46: ...Overview of the P220 Gigabit Switch Family 2 10 Cajun P550 P220 Switch Operation Guide ...
Page 112: ...Configuring IPX Routing Layer 3 4 16 Cajun P550 P220 Switch Operation Guide ...
Page 192: ......
Page 216: ...Configuring AppleTalk Routing Layer 3 10 18 Cajun P550 P220 Switch Operation Guide ...
Page 250: ......
Page 276: ...Monitoring the Cajun Switch Layer 2 Layer 3 16 10 Cajun P550 P220 Switch Operation Guide ...
Page 290: ...A 2 Cajun P550 P220 Switch Operation Guide ...
Page 296: ...Supported MIB Groups B 6 Cajun P550 P220 Switch Operation Guide ...