Remote Port Security Device
User’s Guide
555-024-402
Issue 1
October 1996
Installation
Page 2-20
Testing the RPSD Lock Installation
2
Testing the RPSD Lock Installation
The Self-Check tests the health of the RPSD Lock. If the correct response is
received when the test is run, the RPSD Lock is functioning properly.
Follow these steps to perform the Self-Check:
1. Dial the RMATS channel from a touch-tone telephone.
When the call is answered, you hear a short tone, indicating a connection
to the RPSD Lock.
2. Press
1
✱
on the telephone pad.
If the response is 3 quick tones followed by the RPSD Lock disconnecting,
the Lock is functioning properly.
3. Have the technical support center call the RMATS channel. If access is
successful, the installation is working properly. If access is unsuccessful,
refer to Chapter 5, “Troubleshooting.”
After a successful access of the port has shown the Lock to be working properly,
try dialing out through the RMATS channel via the Lock. If you have trouble with
making an outgoing call, the tip and ring leads probably are reversed. Reverse
the current connection of the tip and ring leads from the central office line to the
RPSD Lock and dial out again. If a failure occurs, something is wrong with the
Lock (see Chapter 5, “Troubleshooting”), and you must replace it.
If all tests are passed successfully, installation is complete for the technician.
Lock initialization can now be performed by the RPSD system administrator.