Remote Port Security Device
User’s Guide
555-024-402
Issue 1
October 1996
Key Administration and Use
Page 4-19
Command Functions
4
S—Status Display
Syntax and Parameters
s
Description
Use the Status Display command to display the current status of the RPSD Key at
the terminal. To use this command, enter
s
at the > prompt.
Sample Command and Response
>s
Lucent RPSD/KEY11 - V1.0 Firmware V2.0xInit Code:
Current Date: Mon 08/14/90Time: 14:28:09Log ID: 12345678
Comms Set to: 9600/8N
Current Status: Idle
The fields of the Status Display screen are:
■
Lucent RPSD/KEY11—gives the version number of the equipment and the
Key user ID.
■
Firmware—gives the version number of the firmware.
■
Init Code—tells where and when the device was initialized.
■
Current Date—gives the current date. If the date is wrong, it can be
corrected by using the Date Set command described in this section.
■
Time—gives the current time. If the time is wrong, it can be corrected by
using the Time Set command described in this section.
■
Log ID—provides the Log ID of the RPSD Key. To set a Log ID, use the Set
Log ID command described in this section.
■
Comms Set To—displays the setting of the communications parameters.
To change the communications parameters, use the Set Communications
Parameters command described in this section. The default setting is
9600 bps at 8 bits, no parity.
■
Current Status—provides the current status of the Key.
Parameter
Description
s
The Status Display command
ENTER
ENTER