Remote Port Security Device
User’s Guide
555-024-402
Issue 1
October 1996
RPSD System Administration
Page 3-47
Command Functions
3
SC—Set Communications Parameters
Syntax and Parameters
sc <speed,length_parity>
Description
Use the Set Communications Parameters command to set the communications
link speed, character length, and parity on the serial port. The default setting is
9600 baud, eight-bit, no parity.
Sample Command and Response
Parameter
Description
sc
Set Communications Parameters command
<speed,
length_
parity>
The communications link speed in bits per second (bps)
and the character length in bps and parity on the serial port.
The options for speed are 300, 600, 1200, 2400, 4800, 9600,
or 19200 bps (trailing zeros may be omitted, for example,
you can enter 24 for 2400 bps). If either
speed
or
length_
parity
are omitted, the current entry is left unchanged.
The following are the options for length/parity (grouped
together):
8N = 8 bits no parity
7N = 7 bits no parity
7E = 7 bits even parity
7O = 7 bits odd parity
ENTER
> sc 1200,7E
JPLock02 005 08/17/96 15:48:21 Comms Params Changed to 1200/7E