LUBING Floor Watering System
- 10 -
3.5 Fitting the Main Water Supply
Overview on page 10, section 1
Protect from frost.
Frost can destroy the components!
For versions with solenoid valve:
Fit switching cabinet in such a way that it is protected
from water!
The Main Water Supply should be attached in such a way that it is always protected
from frost.
For versions with a solenoid valve, the standard version of the time relais must be
connected to a mains voltage of 240 V 50 Hz via the mains plug.
Please note the information on mains voltage on the delivery note.
The components required for the Main Water Supply are supplied ready-assembled.
The attachment (a stable metal console [1]) guarantees a firm, secure and
waterproof connection of the components. The Main Water Supply can therefore be
installed on the wall, usually in the front part of the building. The 6 drill holes [4] in the
metal console are 10 mm in diameter.
The flange connections [2] permit easy exchange of individual components. The
connections to the Main Water Supply are provide d by the ¾" internal screw threads
of the Ball Valves (inlet and outlet [3]).