Chapter 5. Loader
5-1
5.
Loader
5.1
Configuration
Note
STOP key of the inverter iE5 also contains reset function, which is used to cancel trip. Trip may be cancelled by
using this key.
Display
Description
FWD
‘On’ during forward run
REV
‘On’ during reverse run
SET ‘On’
during
parameter
setting
RUN
‘On’ during inverter operation
Blinks when a fault occurs
7 Segments
Displaying operation status and parameter information
Key
Name
Description
S
Up
Scroll through codes or increase parameter value
T
Down
Scroll through codes or decrease parameter value
RUN Run
Operation
command
STOP
Stop
STOP : stop during operation, RST : reset in case of fault
FUNC
Function
Edit parameters or save edited parameter values
SHFT
Shift
Move among groups/the number of ciphers left during parameter setting
Volume resistance
Used to change driving frequency
FWD/REV LED
SET LED
RUN LED
7 Segment LED
UP, DOWN
SHFT
FUNC
RUN,STOP/RESET
Volume Resistance