Chapter 14. COM Option (RS-485)
14-12
z
PROGRAM group
Address
16bit
10bit
Code Parameter
Initial
Max.
Min.
D201 53761 P
1 Last
Fault1
0
1
0
D202 53762 P
2 Last
Fault2
0
1
0
D203 53763 P
3 Last
Fault3
0
1
0
D204 53764 P
4 Fault
Clear
0
1
0
D205 53765 P
5 Run
Prohibit
0
2
0
D206 53766 P
6 ACC
Pattern
0
1
0
D207 53767 P
7 DEC
Pattern
0
1
0
D208 53768 P
8 Stop
Method
0
2
0
D209 53769 P
9 DcBr
freq
500 6000
startFreq
D20A 53770 P
10
DcBlk
time
10
6000
0
D20B 53771 P
11 DcBr
value
50
200
0
D20C 53772 P
12 DcBr
time
10
600
0
D20D 53773 P
13 DcSt
value
50
200
0
D20E 53774 P
14
DcSt
time
0
600
0
D20F 53775 P
15
Jog
Freq
1000 Max.
Freq.
0
D210 53776 P
16
Max
Freq
6000 12000
4000
D211 53777 P
17
Base
Freq
6000 12000
3000
D212 53778 P
18
Start
Freq
50
1000
10
D213 53779 P
19
Trq
Boost
0
1
0
D214 53780 P
20
Fwd
Boost
50
150
0
D215 53781 P
21
Rev
Boost
50
150
0
D216 53782 P
22
VF
Pattern
0
1
0
D217 53783 P
23
OV
adj
100 110
40
D218 53784 P
24
OLT
select
0
1
0
D219 53785 P
25
OLT
level
180 200
50
D21A 53786 P
26
OLT
time
600 600
0
D21B 53787 P
27
Stall
prev.
0
7
0
D21C 53788 P
28 Stall
level
150
150
30
D21D
53789
P 29 Up/Down Save select
0
1
0
D21E
53790
P 30 Up/Down Save Freq.
0
Max. Freq.
0
D21F
53791
P 31 Dwell freq
500
Max. Freq.
startFreq
D220 53792 P
32
Dwell
time
0
100
0
Summary of Contents for SV-iE5 Series