P a g e 32 | 36
LPS-Lasersysteme Siegmund Ruff / CEO Haidschwaerze 18 72131 Ofterdingen Germany
Phone: +49 7473 271177 www.lps-laser.de [email protected]
11.
Safety devices
SimPlex laser systems have all required safety equipment according to DIN EN-60825-1.
11.1
Emergency-Interlock (Remote)
The laser system is to connect via the "remote" connector (6) with an emergency off switch with
opener contact. The laser output is possible only if the two pins are connected. The supplied jumper
plug can be used only for service purposes.
11.2
Key-Switch-Interlock (Remote)
With the key switch "LOCK" (7) the laser system can be unlocked. A laser output is possible only in
position on (green dot). The key can only be removed in position OFF (red dot).
11.3
Scanner-Safety
SimPlex laser systems are equipped with a scanner control, which prevents the output of too small
animations or even a related beam.
12.
Maintenance
Dust, nicotine, fog fluid, etc. cause deposits on mirrors, particularly in discotheques. This
might evoce a substantial decrease in laser power. Room mirrors as well as the mirrors in
the optical bench and its pane are concerned. Even during open air events deposits may
emerge.
Therefore a professional and periodic cleaning is essentail!
LPS-Lasersysteme recommends a regular service, which should be implemented at least
once a year by a technician.
If you want to clean the mirror more than the prescribed annual period, it should be done
only with special introduction! For this purpose LPS-Lasersysteme accepts no liability!
According to the BGV B2 one service by the manufacturer is provided annually!
Because:
-
A complete professional check of the system by an expert can prevent minimum technical
errors and / or attrition with large consequences. A small malfunction can be located and
repaired in advance.