P a g e 13 | 36
LPS-Lasersysteme Siegmund Ruff / CEO Haidschwaerze 18 72131 Ofterdingen Germany
Phone: +49 7473 271177 www.lps-laser.de [email protected]
2.5
Audience Area
In the audience area, the maximum permissible values for radiation and radiation intensity must
never be exceeded.
People must never be exposed to laser radiation that exceeds the highest allowed level.
The operator has to make sure by technical or organizational measures that laser radiation as well as
reflected laser radiation does never exceed the allowed level.
2.6
Show laser area
The initial installation is performed by LPS-Lasersysteme.
Nevertheless, the following steps have to be carried out by the laser protection
representative every time before starting:
Before using the laser system, the device must be examined by a visual inspection if safety-relevant
modifications have been made.
This contains the following topics:
Is the laser system in the same position it was installed in?
Are there no inflammable articles, like decoration, in the path of the beam?
Is the housing of the system closed?
Are all plugs plugged in, particularly all energized plugs, and have they no safety deficiencies as for
example defect of the casing or isolation?
If one of the problems mentioned above did occur, the laser system must be immediately repaired.
Please contact LPS-Lasersysteme (phone: +49 7473 271177).
When operating show lasers, there is a hazard zone, the so-called laser saftey area, in which the laser
radiation duration and power might be higher than the highest allowed level. This area must never
be entered by unauthorized persons.
The laser saftey area must only be entered by trained and authorized persons. Suitable protective
measures must be carried out.
If it is unavoidable to enter the show laser area, it has to be guaranteed that the laser saftey area can
only be entered from instructed and authorized persons. In this case suitable preventive measures
must be observed. If it is necessary for the stage scene that persons stay in the show laser area,
suitable preventive measures are to be observed to avoid endangerments, e. g. and by marked
positions.
The geometric borders of the laser saftey area must be calculated or measured before starting the
operation.