21

Assembling instructions and maintenance

22004022 - 06.13

2. General instructions for end user

DANGER !

GENERAL DANGER

Installation

Before performing any work on this unit, the power supply must be disconnected from the mains.

Installation must be performed in compliance with all applicable local laws and regulations.

The liability of the manufacturer is limited to the supply of the product. Its installation must be performed by qualified personnel working

for a company that system. Installation must be carried out in accordance with best practice and the instructions herein and to the highest

professional standards.

LOVATO S.p.A. disclaims any and all liability for any unauthorized modifications or alterations made to the product or if non-genuine spare

parts are used.

Electrical connection

The controller and the entire system may only be installed and connected by qualified personnel in compliance with all applicable laws

and regulations.

Connect the power supply cable of the controller to a two-pole switch equipped with fuses (power supply 230Vac 50Hz). Ensure proper

connection to the grounding system.

Danger

The controller must be connected to the mains with a residual current circuit-breaker fitted upstream, according to applicable regulations.

Proper operation of the controller is guaranteed

only if it is used in conjunction with the motor for which it was designed. Improper use of this unit will relieve the manufacturer of all liability.

Hydraulic connection

After transporting the KIT, or after handling it, tighten all tube union nuts.

Take extreme care when connecting the KIT to the hydraulic system. Avoid bending the copper tubing. To counteract the tightening force

exerted on the tubing connecting the KIT and the hydraulic system, use a spanner or similar tool on the KIT end.

Please read this manual carefully before performing any work on this equipment.

As a part of our policy of continuous product improvement in order to keep up with innovations in technology and to meet specific manufacturing,

installation or positioning requirements, we reserve the right to make modifications to this product without prior notice. Therefore,

although the product delivered may slightly differ from the illustrations shown in this manual, its safety is guaranteed and the instructions

affixed on it are guaranteed to be correct.

This user manual is an integral part of the product. It must be kept in good condition and must be saved for future reference during the

entire service life of this equipment.

Furthermore, it should always be available near the equipment for quick reference and it must accompany it if it is sold or transferred to a

new owner, or if you move and leave the equipment behind, in order to enable the new owner or technician to use it for reference.

Preliminary inspections

Before anything else, remove the packaging and check that the equipment is in perfect condition. If you find a defect or damage, do not

install it or attempt to fix it yourself and instead contact your dealer.

Dispose of the packaging materials in compliance with applicable regulations on disposal.

Please follow these vital recommendations when using the equipment:

• Do not touch hot surfaces, such as water inlet and outlet ducts. Hot parts may cause severe burns.

• Do not spray the unit with water or other liquids.

• Do not place any items on the top of the unit.

• Do not expose the unit to steam from cooking equipments.

• Do not allow children or inexperienced people to use this equipment.

• Do not touch this equipment with wet or damp parts of the body and/or with bare feet..

• Do not pull electric wires

• Beware of wearing gauntlets and accident-prevention shoes before handling the product

Installation, connection and testing may only be performed by qualified personnel working in 

accordance

!

Dear Customer,

Thank you for choosing a product by Lovato. We are confident that we will reward the trust you have placed in us, thanks to a product that is the result of on-going research and careful,

quality-oriented manufacturing.

All of our products are manufactured using top-grade materials and components ensuring long-lasting quality and reliability.

In addition to the product’s features and specifications, this document contains instructions addressed to the installer and service technicians, as well as to the end user.

Please note that after installation you should contact our local Customer Service team, who will commission the equipment and validate and confirm the relevant warranty. For your nearest

Customer Service Centre, please call us on (0039) 045 6182012.

For perfect set-up and conscientious periodic maintenance we recommend that you contact one of our Authorized Customer Service Centres at least once a year. Our Service team will not

only carry out a thorough overhaul of the thermal module, but will also perform preventative maintenance in order to prevent problems or unwanted deactivations.

We thank you again for choosing one of our products and we will be more than happy to provide you with any further information and support you may require for the proper operation of

this equipment.

         LOVATO 

S.p.A.

Summary of Contents for BIG EXOL AR2

Page 1: ...autorizzazione scritta Picture and technical data are not binding LOVATO SpA will reserve the right to bring change without obbligation of notice It is forbidden reproduce copy drawing or texties part...

Page 2: ...licazione 9 Riempimento impianto 10 Descrizione quadro comandi 11 Messa in funzione 12 Impostazioni iniziali della centralina 13 15 Tabella parametri centralina Software di supervisione 16 17 Componen...

Page 3: ...ore elettronico XTDC Misuratore di pressione temperatura RPS 1 8 bar Circolatore Wilo STRATOS PARA 30 1 8 circuito di riscaldamento Rubinetto di carico scarico Valvole a sfera circuito riscaldamento i...

Page 4: ...a 30 1 12 3000 4000 5000 6000 Wilo Stratos Para 30 1 8 DP primario Primary DP DP secondario Secondary DP Resa circuito secondario Dt secondario DT secondary 0 P m H 2 O P kPa 11 13 16 18 Portata secon...

Page 5: ...con cura per ogni ulteriore consultazione anche nel caso in cui quest ultimo dovesse essere venduto o trasferito ad altro proprietario o si dovesse traslocare e lasciare l apparecchio in modo che il...

Page 6: ...avere un elevata pressione Prima di effettuare un eventuale smontaggio bisogna svuotare il contenuto d acqua del sistema e chiudere le valvole di intercettazione L installazione e ogni eventuale inter...

Page 7: ...evitare inutili dispersioni di calore si consiglia il posizionamento del modulo il pi vicino possibile all accumulo tampone e su una superficie adeguata a sorreggere il peso dello stesso Assicurarsi d...

Page 8: ...8 Installazione uso e manutenzione 22004065 09 13 5 Esempio di applicazione 5 Schema idraulico...

Page 9: ...letamente l aria presente nel circuito per una migliore resa dell impianto 2 Riempire il circuito secondario ed evacuare l aria presente nel circuito mediante le valvole di sfiato manuale 3 Controllar...

Page 10: ...nterruttore magnetotermico I cavi collegati alla centralina non devono essere scoperti per pi di 55mm e il rivestimento del cavo deve entrare nella copertura fino all altro capo della fascetta di rinf...

Page 11: ...Sfiato e spurgo dell impianto Aprire una presa d acqua tecnica con distribuzione situata in prossimit dell impianto Lo sfiato sul lato riscaldamento secondario avviene mediante opportuno dispositivo s...

Page 12: ...oni per le varie applicazioni 1 2 3 4 Il display 1 con testo esteso e modalit grafica quasi auto esplicativo permet tendo un facile utilizzo della centralina Per uscire dal menu delle impostazioni pre...

Page 13: ...90 C 5 2 4 T max acc 2 90 C 5 3 Raffreddamento 5 3 1 Raffreddamento on 5 3 2 Temp attivazione raffreddamento 85 C 5 4 Antigelo 5 4 1 Antigelo off 5 5 Antibloccaggio 5 5 1 Antibloccaggio R1 off 5 5 2 A...

Page 14: ...el 5 6 7 Rel 5 6 8 Rel 5 6 9 Contabilizzazione 6 9 1 Portata fissa 6 9 1 1 Contabilizzazione off 6 9 2 VFS1 6 9 2 1 Tipo VFS1 10 200 l min 6 9 2 2 Installato su ritorno 6 9 2 3 Sonda riferimento S2 6...

Page 15: ...re i dati di funzionamento dell impianto Soprattutto quest ultima funzione abbinata al software di supervisione Sorel Connect per maggiori dettagli vedere paragrafo successivo di fondamentale importan...

Page 16: ...circuito secondario Valvola a 3 vie deviatrice motorizzata inserita in uscita circuito secondario gestisce a seconda del valore di tem peratura delle sonde S1 S2 la priorit verso il puffer 1 o il puf...

Page 17: ...presente nella confezione Portata secondario Secondary flow rate l h 0 P m H 2 O P kPa Resa circolatore Pump efficiency 2000 3000 4000 5000 6000 7000 10 20 30 40 50 60 70 80 90 100 Efficienza pompa se...

Page 18: ...application example 9 Machinery filling 10 Control panel description 11 Start up 12 Electrical regulator initial settings 13 15 Control unit parameters table Software 16 17 Components Indicx Picture...

Page 19: ...mperature measuring RPS 0 5 3 bar Pump Wilo STRATOS PARA 30 1 8 of heating circuit Fill drain cock heating circuit Ball valve of heating circuit in sanded OT F F 1 1 2 Fill drain cock solar circuit Ma...

Page 20: ...ra 30 1 12 3000 4000 5000 6000 Wilo Stratos Para 30 1 8 DP primario Primary DP DP secondario Secondary DP Performance of secondary circuit Dt secondario DT secondary 0 P m H 2 O P kPa 11 13 16 18 Port...

Page 21: ...ference during the entire service life of this equipment Furthermore it should always be available near the equipment for quick reference and it must accompany it if it is sold or transferred to a new...

Page 22: ...t and at high pressure Beware of emptying the water inside the system and locking the check valves before disassembling The installation and any possible intervention have to be made according to loca...

Page 23: ...ecommended In order to avoid any unnecessary waste of energy the placement of this module as close as possible to intermediate tank is recommended The used surface must be adequate to module s weight...

Page 24: ...24 Assembling instructions and maintenance 22004022 06 13 5 Application example 5 Hydraulic diagram...

Page 25: ...ng the air inside the circuit entirely for a better system performance 2 Fill the secondary circuit and evacuate the air inside it through manual air valves 3 Check if the module is watertight 4 Put t...

Page 26: ...nit must not be uncovered for more than 55mm and their covering must fit in the protection up to the other strip extremity Warning Warning Warning 7 Control panel description Warning SD Card Slot for...

Page 27: ...revious paragraph Venting and flushing of system s circuits Open a non drinkable water tab close to the module until venting is completed Venting on heating secondary side can be typically carried out...

Page 28: ...4 The display 1 with its extensive text and graphics mode is almost self explanatory allowing easy operation of the controller To change from the overview to the settings menu press the esc key The gr...

Page 29: ...ttore on 110 C 100 C 5 2 3 Puffer 1 max temp 90 C 5 2 4 Puffer 2 max temp 90 C 5 3 Cooling 5 3 1 Cooling on 5 3 2 Cooling activation temp 85 C 5 4 Antifreeze 5 4 1 Antifreeze off 5 5 Antilock 5 5 1 An...

Page 30: ...6 6 Relay 5 6 7 Relay 5 6 8 Relay 5 6 9 Accounting 6 9 1 Fixed flow rate 6 9 1 1 Accounting off 6 9 2 VFS1 6 9 2 1 Type VFS1 10 200 l min 6 9 2 2 Installed on return 6 9 2 3 Sonda riferimento S2 6 9...

Page 31: ...be used for possible firmware updates or data storage as regards system operations Especially for what concerns this last function when the Micro SD is combined with Sorel Connect check next chapter...

Page 32: ...elivery circuit The 3 ways deflecting and motorised valve inserted in the secondary circuit output handles the priority towards puffer 1 or puffer 2 diagram 17 according to temperature value of the pr...

Page 33: ...ual included in the packaging Portata secondario Secondary flow rate l h 0 P m H 2 O P kPa Resa circolatore Pump efficiency 2000 3000 4000 5000 6000 7000 10 20 30 40 50 60 70 80 90 100 Secondary pump...

Page 34: ...lage 10 Beschreibung des Schaltschranks 11 Inbetriebnahme 12 Voreinstellung elektronischer Regler 13 15 Tabelle Steueraggregat Parameter berwachungssoftware 16 17 Komponente Verzeichnis Abbildungen un...

Page 35: ...tungsschutzschalter Elektronischer Regler XTDC Druck Temperaturmessger t RPS 0 5 3 bar Pumpe Wilo STRATOS PARA 30 1 8 Heizungskreis KFE Hahn Heizungskreis Valvole a sfera circuito riscaldamento in OT...

Page 36: ...atos Para 30 1 8 DP primario Primary DP DP secondario Secondary DP Leistung Sekund rkreis Dt secondario DT secondary 0 P m H 2 O P kPa 11 13 16 18 Portata secondario secondary flow rate l min 110 115...

Page 37: ...reit in Ger ten he befinden und sorgf ltig f r alle weiteren Konsultierungen aufbewahrt werden auch im Fall dass das Ger t weiterverkauft wird oder an einen anderen Besitzer bergeht oder bei Umzug und...

Page 38: ...nn sehr hei sein und einen hohen Druck haben Vor einer eventuellen Demontage der Einheit unbedingt Wasser entleeren und Absperrventile schlie en Installation sowie alle Eins tze an der Einheit unbedin...

Page 39: ...rmeaussch ttung zu vermeiden wird es geraten die Einheit so nah wie m glich zum Puffertank zu positionieren jedoch muss der Boden f r das Gewicht der Einheit geeignet sein Halterungsf ssen korrekt ein...

Page 40: ...40 Montage und Wartungsanleitung 22004022 06 13 5 Anwendungsbeispiel 5 Hydraulikplan...

Page 41: ...uslassen um eine bessere Leistung der Anlage zu garantieren 2 Sekund rkreis einf llen und Luft in der Anlage mittels manueller Auslass ventile auslassen 3 Hydraulische Dichtheit der Einheit berpr fen...

Page 42: ...Kabel muss untere den Deckel bis zu der Befestigung eingesteckt werden Achtung Achtung Achtung 7 Beschreibung des Schaltschranks Achtung Slot der SD Karte F r Data Log und Firmware Aktualisierungen Si...

Page 43: ...im vorherigen Paragraph beschrieben Anlage entl ften und reinigen Wasser aufmachen in der N he der Anlage DerAuslass an der Heizungsseite Sekund rkreis erfolgt mittels Vorrichtung am oberen Teil der P...

Page 44: ...itere Einstellungen f r die verschiedenen Anwendungen erforderlich sind 1 2 3 4 Der Display 1 mit ausf hrlichem Text und grafischer Modalit t ist selbsterkl rend und erm glicht eine einfache Bedienung...

Page 45: ...C 5 3 K hlung 5 3 1 K hlung on 5 3 2 Temp Aktivierung K hlung 85 C 5 4 Frostschutz 5 4 1 Frostschutz off 5 5 Antiblockiersystem 5 5 1 Antiblockiersystem R1 off 5 5 2 Antiblockiersystem R2 off 5 5 3 An...

Page 46: ...By pass Solaranlage Ausw hlen 6 6 Relais 5 6 7 Relais 5 6 8 Relais 5 6 9 Mengenz hler 6 9 1 Fixer Durchfluss 6 9 1 1 Mengenz hler off 6 9 2 VFS1 6 9 2 1 Typ VFS1 10 200 l min 6 9 2 2 Installiert auf...

Page 47: ...Aktualisierungen des Firmwares zu verwenden oder um die Funktionsdatei der Anlage zu speichern Diese letzte Funktion zusammen mit der SORELConnect Software siehe nachfolgendes Paragraph ist besonders...

Page 48: ...torisierter 3 Wege Umlenkventil angebracht am Ausgang des Sekund rkreises diese dient zur Verwaltung aufgrund der Temperatur der F hler S1 S2 der Priorit t zum Puffer 1 oder 2 siehe Schema 17 Es ist a...

Page 49: ...ten Portata secondario Secondary flow rate l h 0 P m H 2 O P kPa Resa circolatore Pump efficiency 2000 3000 4000 5000 6000 7000 10 20 30 40 50 60 70 80 90 100 Pumpeneffizienz Sekund rkreis Leistung pu...

Page 50: ...age quipement 26 Description du panneau de commandes 27 Mise en service 28 R glages initiaux du r gulateur lectronique 29 31 Tableau des param tres de la centrale Logiciel de supervision 32 33 Composa...

Page 51: ...nique XTDC Mesureur de pression temp rature RPS 0 5 3 bars Pompe de circulation Wilo STRATOS PARA 30 1 8 circuit de chauffage Robinet de remplissage vidange Vannes boisseau sph rique circuit de chauff...

Page 52: ...88 2 98 0 107 8 117 6 Wilo Stratos Para 30 1 12 3000 4000 5000 6000 Wilo Stratos Para 30 1 8 DP primaire DP secondaire Rendement circuit secondaire Dt secondaire 0 P m H 2 O P kPa 11 13 16 18 D bit se...

Page 53: ...soit conserv avec soin pour garantir toute consultationult rieure m meencas deventedel appareillageoudetransfert unautrepropri taireousivousd m nagezetquevouslaissiez sur place celui ci de fa on ce qu...

Page 54: ...ieur du BIG EXOL peut tre tr s chaude et avoir une pression lev e Avant tout d montage ventuel il est n cessaire de vider le contenu en eau du syst me et de fermer les vannes d interception L installa...

Page 55: ...re 40 C Pour viter des pertes de chaleur inutiles nous recommandons le positionnement du module le plus proche possible du ballon tampon et ce sur une superficie appropri e apte supporter le poids de...

Page 56: ...56 Instructions relatives l installation l utilisation et la maintenance 22004022 06 13 5 Exemple d application 5 Sch ma hydraulique...

Page 57: ...f 1 2 en enlevant compl tement l air pr sent dans le circuit pour un meilleur rendement de l quipement 2 Remplir le circuit secondaire et faire vacuer l air pr sent dans le circuit par l interm diair...

Page 58: ...us les p les par exemple un disjoncteur Les c bles connect s la centrale ne doivent pas tre d pouill s de leur rev tement de plus de 55 mm et le rev tement du c ble doit entrer dans le recouvrement ju...

Page 59: ...on et purge de l quipement Ouvrir une prise d eau technique avec distribution situ e proximit de l quipement La purge sur le c t de chauffage secondaire se produit travers le dispositif appropri habit...

Page 60: ...4 L cran de visualisation 1 quip des modes texte et graphique exhaustifs permet une utilisation du r gulateur simple et qui n appelle pratiquement pas d explications Pour sortir de la vue d ensemble...

Page 61: ...ecteur on 110 C 100 C 5 2 3 T max ballon 1 90 C 5 2 4 T max ballon 2 90 C 5 3 Refroidissement 5 3 1 Refroidissement on 5 3 2 Temp activation refroidissement 85 C 5 4 Antigel 5 4 1 Antigel off 5 5 Anti...

Page 62: ...1 By pass solaire s lectionner 6 6 Relais 5 6 7 Relais 6 6 8 Relais 7 6 9 Comptabilisation 6 9 1 D bit fixe 6 9 1 1 Comptabilisation off 6 9 2 VFS1 6 9 2 1 Tipo VFS1 10 200 l min 6 9 2 2 Install sur...

Page 63: ...ent Cette derni re caract ristique surtout associ e au logiciel de supervision Sorel Connect pour plus de d tails consultez le paragraphe suivant est essentielle pour surveiller superviser le bon fonc...

Page 64: ...nt du circuit secondaire Vanne 3 voies d viatrice motoris e ins r e dans la sortie du circuit secondaire qui g re en fonction de la valeur de la temp rature des sondes S1 S2 la priorit vers le ballon...

Page 65: ...sont disponibles dans le manuel d instructions Wilo pr sent dans le carton d emballage D bit secondaire l h 0 P m H 2 O P kPa Pumpe efficacit 2000 3000 4000 5000 6000 7000 10 20 30 40 50 60 70 80 90 1...

Reviews: