INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND USE
Rev-09
PM.IE 8-9-1-R-GN-DU-GB-09
12
ELECTRIC KETTLES INDIRECT
“PM8-9IE..A” “PM1IE..A” “PMRIE..A” “PM9IE..GN”
3 USE
AND
CLEANING
3.1
WARNINGS AND HINTS FOR USER
−
This manual contains all the instructions required for a proper and safe use of our appliances.
−
Keep the manual in a safe place for future consultation!
−
This appliance is for catering use, hence they must be used only by trained kitchen staff.
−
The appliance must always be kept under control during use.
−
Warning! : The manufacturer shall not be held responsible for injuries or damage due to the non-
compliance with safety rules or an improper use of the appliance by the operator.
−
Some improper operating conditions may even be caused by an improper use of the appliance, therefore it
is important to train personnel properly.
−
All the installation and maintenance operations must be performed by fitters who are members of
an official register.
−
Respect the periods required for maintenance. With this is mind, customers are recommended to sign a
service agreement.
−
In case of failures concerning the appliance, all outputs (electrical power supply and water) must be cut off
instantly.
−
In case of recurrent failures, contact a service technician.
3.2 INSTRUCTIONS
FOR
USE
−
Before cooking with the appliance for the first time, wash the interior of the cooking vat
thoroughly.
Warning! :
Fill the cooking vat up to a maximum of 40 mm under the overflow border, according to
the maximum level mark, including the food to be cooked.
Warning! :
Before filling the vat, always check that the drainage tap is closed.
3.2.1
FILLING THE JACKET
MOD. 100-150 lt
Warning! :
The water level in the jacket must be checked each time before lighting.
Warning! :
It is advisable to use softened water to fill the jacket!
−
Open the level tap on the front of the appliance.
−
Unscrew the filling cap on the safety valve unit. The latter is on the right of the appliance surface (see
figure “Size of appliance and position of connections ”).
−
Fill with softened water (the capacity of the jacket is stated in the paragraph “Technical data”).
−
When water flows out of the level tap, close it and screw back on the safety unit cap.
Mod. PM1IE200/300/500 – PMRIE100/150/200/300/500/510 – PM9IE170/270/370GN
Warning! :
The water level in the jacket must be checked each time before lighting.
Warning! :
It is advisable to use softened water to fill the jacket!
−
Open the level tap on the front of the appliance.