Configuration
ALARM SETUP
1.
CHANNEL
- Select a channel for the setup.
2.
ALARM INPUT
- Set up the Alarm Input type.
• NORMALLY CLOSED - The Alarm is triggered
when the circuit is closed (ON).
• NORMALLY OPEN - The Alarm is triggered
when the circuit is opened (OFF).
3.
DURATION
- Setup for the post-alarm recording
duration, and the alarm output duration. The
duration setting is applied to both functions. The
setting range is from 1 second to 99 seconds.
NOTE
: Alarm output can be triggered by alarm input
and video loss. Motion cannot trigger an alarm
output.
INTERVAL SETUP
1.
SEQUENCE SCREEN
- Full Screen Sequence
Interval setup (1~99 SEC).
2.
PIP SCREEN
- Picture in Picture- setup for the
sub-picture’s sequence interval (1~99 SEC).
3.
EVENT UPDATE
- The Event Update Time
prevents the system from recording the event logs
from the same event. The event types include A
• Alarm
• Motion
• Video loss.
When an event is triggered, it is possible that the
same event type continues to be triggered for a
period of time (i.e. Motion starts, then stops for a
short period, then starts again).
With the Event Update Time setting, whenever
there is an event, the system records the starting
time and information of the event in the Event Log,
and ignores the following events within the duration
set in the Event update time. The setting range of
the Event Update time is from 10 seconds to 990
seconds.