Start-up
- 49 -
10.13
13 .5 Main parameters
Parameter
Symbol
Code
Factory setting
Range
Wire feed in %
(positive correc-
tion)
0
-80..
+99
Wire feed in %
(negativecorrec-
tion)
Displayed as correction value for settings at
turning knob 61.
Wire feed in
m/min
-
-
0,5..
25
Displayed as speed value in m/min after
setting with turning knob 61.
Material thick-
ness (at selected
characteristic
line)
-
-
-
Must-value weld
-
ing voltage (in
manual mode,
only Control Pro)
V
-
-
-
Welding step (in
manual mode)
-
-
1..6,
1..7
1..12
Tab. 6:
Main parameters
13 .6 Secondary parameters
Â
Press the mode key 60 for at least 2 sec
-
onds.
9
The 7-segment display 47 displays the
secondary parameter code and value al
-
ternately (BasicPlus).
9
The 7-segment display 47 displays the sec
-
ondary parameter value, the 7-segment
display 55 displays the secondary param
-
eter code (ControlPro).
Â
Press the mode key 60 until the required
secondary parameter code is displayed.
Â
Set the required secondary parameter
value using turning knob 61.
Â
Exit the secondary parameter by pressing
the mode key 60 for at least 2 seconds.
Parameter Code
Factory
setting
Mode
Range
2-stroke 4-stroke
Spot Interval
Gas pre-flow
0,1 s
x x x x
0,0...10,0 s
Creep in
speed
2,0 m/min
x x x x
1,0...15,0
m/min
Spot welding
time
1,0 s
x
0,1...10,0 s
Backburn time
100 %
x x x x
0...300 %
Gas post-flo
0,5 s
x x x x
0,1...20,0 s
Intervalltime
ON
1,0 s
x
0,1...10,0 s
Interval time
OFF
0,2 s
x
0,1...1,0 s
Software Ver
-
sion
-
x x x x
Must-value
welding volt
-
age instead of
material thick
-
ness
off
x x x x
off/on
Tab. 7:
Secondary parameters
Summary of Contents for M-Pro BasicPlus
Page 43: ...Before start up 43 10 13 ...
Page 71: ...Antes de la puesta en funcionamiento 71 10 13 ...
Page 99: ...Voor de inbedrijfstelling 99 10 13 ...
Page 157: ...Avant la mise en service 157 10 13 ...
Page 185: ...Před uvedením do provozu 185 10 13 ...
Page 213: ...Prima di cominciare 213 10 13 ...
Page 287: ...Ersatzteilliste spare parts list Список деталей 287 10 13 ...