Before start-up
- 38 -
10.13
12 Before start-up
12 .1 Connecting the torch
Â
Connect the central connector 17 of the
torch to the central socket 11.
17
11
Abb. 2:
Connecting the torch
12 .2 Connecting the ground cable
Â
Connect welding return cable 18 to con
-
nector 10 and secure it by turning it clock
-
wise.
10
18
Abb. 3:
Connecting the ground cable
12 .3 Select mains voltage
(Only for machines with mains voltage
switch-over, refer to technical data )
Â
Set the required voltage by using mains
voltage switch 4.
For 230 V operation, the adapter CEE 16
on shock proof plug (incl. in delivery) may
be used.
Performance values are limited
in 230 V mode, i.e. max welding
power is limited to 2/3 of the values
stated in technical data.
12 .4 Fastening the ground clamp
Abb. 4:
Correct
Â
Attach the ground clamp immediately be
-
side the welding point so that the welding
current will not try to find its own return
path through machine parts, ball bearings
or electric circuits.
Â
Connect the ground clamp firmly to the
welding bench or the workpiece.
Abb. 5:
Incorrect
Do not place the ground clamp on the
welding machine or the gas cylinder; oth
-
erwise the welding current will be carried
via the protective conductors and it will
destroy these.
i
Summary of Contents for M-Pro BasicPlus
Page 43: ...Before start up 43 10 13 ...
Page 71: ...Antes de la puesta en funcionamiento 71 10 13 ...
Page 99: ...Voor de inbedrijfstelling 99 10 13 ...
Page 157: ...Avant la mise en service 157 10 13 ...
Page 185: ...Před uvedením do provozu 185 10 13 ...
Page 213: ...Prima di cominciare 213 10 13 ...
Page 287: ...Ersatzteilliste spare parts list Список деталей 287 10 13 ...