Installation
(for qualified installers only)
61
© Travis Industries
11/9/20 - 1478
PB 72 GSB2/GSR2 Aust.
CoolSmart TV - Installation Requirements
Grill and Manifold Dimensions
The grill may be installed over the
facing to provide an aesthetic opening
for the convection outlet. (2) 8-32 x 1-
1/2” screws attach the trim to the upper
manifold. This allows variable
thickness of finish material.
Dimensions
a
b
c
d
e
PB 42
45” (1143mm)
2-7/8” (74mm)
1-1/4” (32mm)
44” (1118mm)
1-3/4” (45mm)
PB 54
57” (1448mm)
2-7/8” (74mm)
1-1/4” (32mm)
56” (1423mm)
1-3/4” (45mm)
PB 72
75” (1905mm)
2-7/8” (74mm)
1-1/4” (32mm)
74” (1880mm)
1-3/4” (45mm)
Min. 3-1/2"
(89mm)
Max. 3"
(77mm)
Min. 1/2" (13mm)*
Max. 4-1/4" (108mm)
1-1/4" (32mm)
1-3/4" (45mm)
3/4" (20mm)
3/8" (10mm)
Manifold
Ceiling
Upper Manifold Framing
ProBuilder
Linear
Fireplace
Lower Manifold Framing
Manifold Support Bracket
Fireplace Header
Min. 1" (26mm) Clearance from
Flex Duct to Combustibles
Min. 3-1/2"
(89mm)
Max. 1-1/2" (39mm)
Min. 1-1/2" (39mm)
3-3/4"
(96mm)
5" (127mm) Alum. Flex Duct (included)
Max. 4-1/4"
(108mm)
Min. 1-1/4" (32mm)
Clearance from Top, Sides
and Back to Combustibles
Max. 120"
(3048mm)
Min. 66-1/2"
(1690mm)
* This area may be supported using
1" (26mm) strips of non-combustible
material spaced a minimum of 12"
(305mm).
e
d
b
a
c