22 Installation
(for qualified installers only)
© Travis Industries
11/9/20 - 1478
PB 72 GSB2/GSR2 Aust.
Gas Line Location
NOTE FOR RIGID PIPE:
When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace
and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve. Disconnect
the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed through the cover
plate and the shutoff valve and gas line may be re-attached inside the fireplace.
Gas line may be plumbed from the left side (stock) or below. See illustration and table below to determine gas line
location.
a
b
Stock Shutoff Valve Location (Left side)
6-1/4” (159mm)
2-3/8” (61mm)
Alternative Shutoff Valve Location (through base of fireplace)*
NOTE: You will need to add a longer 3/8” Flex Gas Line
10-1/8” (258mm)
25-3/8” (645mm)
(from each side)
*Relocating the Gas Line to the Base of Fireplace
1. Disconnect the gas line from the shutoff valve (3/4” wrench). Gas line is located inside the fireplace on the left
side.
2. Remove the screw that holds the shutoff valve plate in place (1/4” nutdriver). Remove the shutoff valve plate.
3. Remove the cover plate from the bottom of the fireplace (it is held in place in the same fashion as the shutoff
valve plate). Attach it to the left side of the fireplace.
4. Attach the shutoff valve plate to the bottom of the fireplace. Route the gas line to the bottom and re-attach the
gas line to the shutoff valve. Make sure to leak test the entire gas line.
a
b
TOP OF FIREPLACE
2-1/2" (63mm)
Stock Shutoff Valve Location
(secured to firebox support)
Alternative Shutoff Valve Locations
(secured to firebox floor)
b
a
a