Wall Mount Remote Thermostat installation (optional for GSB2 only)
Installation
If Using the Optional Blower, Install it First
The optional blower should be installed before installing the remote.
1 Remove the lower front access panel from the fireplace by reaching in behind it and
loosening the two wing nuts and (1) ¼” screw on each side of the panel that hold it in place
(see fireplace manual for details.) Lift up and then out on the panel to remove. Lay the panel
face down in front of the fireplace.
2 Remove the 4 screws that secure the dashboard to the fireplace and gently lower it to gain
access to the back side.
NOTE
There should be enough slack in the attached wires to lower the dashboard to the floor. Make
sure not to damage any off the attached wires.
3 Remove the two wires from the back of the on/off switch.
4 Remove the switch from the dashboard by depressing the tabs on the top and the bottom of
the switch housing while pressing the back of the switch forward through the hole in the
dashboard. Replace the switch with the included switch blank (see pictures below).