SECTION 4. DISASSEMBLY AND SERVICE
- 47 -
MAIN WINDING
Using an ohmmeter, measure the resistance
between the AC output terminals.
NOTE:
If the resistance is zero or infinity, replace the stator.
EXCITER WINDING
Using an ohmmeter, measure the resistance
between the Blue and Blue wires in the 4P coupler.
If the resistance is zero or infinity, replace the stator.
DC WINDING
Using an ohmmeter, measure the resistance
between the green wire leads at the DC diode
connecter.
RESISTANCE
5000 0.11-0.16
Ω
6500 0.11-0.16
Ω
8000 0.13-0.18
Ω
If the resistance is out of specification, replace the
stator.
RESISTANCE
5000 0.80-0.98
Ω
6500 0.50-0.61
Ω
8000 0.43-0.53
Ω
(Ⅰ)
- END
∝
RESISTANCE
5000 1.63-2.07
Ω
6500 1.90-2.31
Ω
8000 1.96-2.36
Ω
AC OUTPUT
TERMINALS
BI
R
(Ⅰ)