Operating Instructions
Configuring the Metal Detector
Wherever possible, configuration of the metal detector will be carried out by Loma Systems before the
machine is dispatched, or by a Loma Service Engineer during a commissioning visit. Primarily, the
commissioning visit is required as part of the installation process so that the engineer can optimise
machine performance in its actual working environment and for the products that are to be inspected.
There are circumstances, however, where it may be necessary for the end user to carry out some or
all of the configuration and commissioning procedures. Typically, this would occur when Loma
Systems do not have enough information about the end application, such as the belt speed or reject
details, to fully configure the machine.
Options and parameters available for configuring the metal detector are listed and described below.
■
■
■
Setting Up the Service Options
■
■
■
■
■
■
Setting Up Product Signal Tracking
■
Setting Up the Search Head
To set up the search head, proceed as follows:
1.
Select
Menus > Service > Configuration > Head
to display the
Head
menu options which
are listed and described below.
2.
Use the
Navigation Keys
to select each option in turn press the
OK /
Enter Key
to enable the value to be edited.
3.
Use the
Navigation Keys
to select the required option value and then
press the
OK / Enter Key
to confirm the selection.
4.
Repeat step 2 and 3 until you have selected and confirmed values for each option.
The Head menu options available are as follows:
■
Type
The 'Conveyor' option should be selected for the IQ
3
metal detector search head.
■
Coil gap
The coil gap required can be found on the serial number plate located within the control box of
the detector head. It is set at 0.6 times the smallest aperture dimension, which is generally the
aperture height.
76
Summary of Contents for IQ3
Page 2: ......
Page 10: ......
Page 26: ......
Page 43: ...Installation 33 ...
Page 60: ...Installation THIS PAGE IS INTENTIONALLY LEFT BLANK 50 ...
Page 70: ...About the Metal Detector Range THIS PAGE IS INTENTIONALLY LEFT BLANK 60 ...
Page 74: ...Getting Started IQ3 Dual Line Display Menu Map 64 ...
Page 116: ...Operating Instructions THIS PAGE IS INTENTIONALLY LEFT BLANK 106 ...
Page 140: ...Maintenance THIS PAGE IS INTENTIONALLY LEFT BLANK 130 ...