Operating Instructions
■
Noise Filter
This feature provides options for automatically filtering out background noise which could
affect the identification of contaminants in products. Options of OFF, LOW and HIGH are
provided for selection.
■
Control Board
The control board type that is currently fitted to the detector head is displayed. This is not
editable.
■
RX TX Board
The RX TX board type that is currently fitted to the detector head is displayed. This is not
editable.
Setting Up the Service Options
To set up the service options, proceed as follows:
1.
Select
Menus > Service > Options
to display the
Service Options
menu options which are
listed and described below.
2.
Use the
Navigation Keys
to select each option in turn press the
OK /
Enter Key
to enable the value to be edited.
3.
Use the
Navigation Keys
to select the required option value and then
press the
OK / Enter Key
to confirm the selection.
4.
Repeat step 2 and 3 until you have selected and confirmed values for each option.
The Service Options menu contains the following options:
■
Tracker
Enabling the Tracker functionality allows product threshold values to follow any changes in
measured product effect. This option is only available when a product registration photo-eye
is in use. See
■
Reject time
Selecting this option enables the Reject delay and Reject dwell values to be updated.
Therefore, leaving this option disabled prevents accidental changes being made to the reject
timings.
■
Set Up Learn
Selecting this option enables the Menus > Learn > Set Up menu to be displayed for selection.
■
Access ferrite
Selecting this option allows access to the Ferrite (F) product option in the Menus > Change
menu.
As this product is setup in the factory and its settings used by the detector as the baseline for
inspecting Dry products, access should be disabled to avoid incorrect use.
Access is generally enabled by a Loma Service Engineer when the Ferrite product needs to
be re-learnt following replacement of a circuit board or upgrading of the detector software.
81
Summary of Contents for IQ3
Page 2: ......
Page 10: ......
Page 26: ......
Page 43: ...Installation 33 ...
Page 60: ...Installation THIS PAGE IS INTENTIONALLY LEFT BLANK 50 ...
Page 70: ...About the Metal Detector Range THIS PAGE IS INTENTIONALLY LEFT BLANK 60 ...
Page 74: ...Getting Started IQ3 Dual Line Display Menu Map 64 ...
Page 116: ...Operating Instructions THIS PAGE IS INTENTIONALLY LEFT BLANK 106 ...
Page 140: ...Maintenance THIS PAGE IS INTENTIONALLY LEFT BLANK 130 ...