11. ELECTRIC IGNITION – EMERGENCY
OPERATION
COMFORT FUNCTIONS WITH EXTERNAL ROOM
THERMOSTAT
Your LOHBERGER pellet stove has an interface mounted on the wall
to which you can connect a commercially available room thermostat.
For this you need a two-wire cable with a cross section of 0.5 to
0.75 mm2, which you can connect in place of the cable bridge fitted
on delivery.
To ensure the room thermostat is operating correctly check the set-
tings of the stove in Setup in the menu. As described previously the
external unit “EXT” must be set to ON (active).
This function also allows you to deactivate (set “EXT” to off) a con-
nected room thermostat.
All other room settings that are necessary can be found in the ope-
rating instructions for the room thermostat.
The connected room thermostat must be operated in the HEAT
menu. You can select the heat output you wish for the room tem-
perature selected.
If an external demand for stopping the pellet stove occurs, it takes
about 5 minutes until the pellet stove switches to burn out phase.
10. OPTIONS
We should like to point out that auxiliary equipment connected to
interface (connections and external connection plugs) should only be
fitted by authorized personnel.
ROOM SENSOR – WIRELESS ROOM SENSOR
This option permits control of your pellet stove via a room tempera-
ture. You can set both the room temperature and the heating times
required. The temperature you selected is maintained during the
heating times. Please see the operating instructions for the option
room sensor and wireless room sensor for more detailed informa-
tion.
TELEPHONE OPTION – GSM
Your pellet stove can also be started via a mobile phone as an
additional option. Please see the operating instructions for the tele-
phone option – GSM for more detailed information.
Not available at INDALO
The pellet furnace is fitted with an electric ignition. This starts to
function together with the stove start program. Ignition duty cycle:
Approx. 6 min.
EMERGENCY OPERATION – HEATING UP WITHOUT
ELECTRICAL IGNITION
If the ignition cartridge of the unit fails, emergency operation may
be performed using fire lighters. Place a handful of pellets with the
fire lighter in the cleaned fire trough, ignite them and then close the
combustion chamber door. Pressing the
- key starts the stove.
CAUTION: Do not use flammable liquids to preheat the stove!
SOME FIELD VALUES
A full pellet container will suffice approximately 7,5 hours at an
output of 100% and approximately 25 hours at an output of 30%.
(variations are possible in case of pellet quality).
Please contact your dealer if you have any questions.
Pellet consumption depends on the size of the pellets. The
larger the pellets the slower the feed and vice versa.
FUEL ADDITION
CAUTION when filling the stove with pellets! Do not touch the
hot stove with the pellet sack. Remove any pellets that have
not been put in the storage container immediately!
To prevent the fire from going out due to lack of fuel, we recommend
that an adequate filling level is kept in the storage container. Check
the filling level often. The container lid should however always be
kept closed unless the container is being filled.
Pellet container capacity (see
“Technical data”)
For the external thermostat it must be a potential-free „open/close“
contact.