background image

English

40

Key 

Display

Description

SETUP

Display to enter the control level for additional functions. You can change between the operating status ON (active) and 
OFF (inactive).

FROST OFF

Display of operating status of additional function FROST, frost protection (only in connection with room sensor and wi-
reless room sensor). Using 

+

 and 

-

 you can switch between FROST OFF (inactive) and FROST ON (active). Frost 

protection is only active in combination with the comfortfunctions HEAT OFF, ROOM OFF and AUTO OFF. Starting tempe-
rature 8°C, stopping temperature 13°C.

Menü

EXT OFF

Display of operating status of additional function EXT external unit such as e.g. a customary room thermostat (see COM-
FORT FUNCTIONS WITH EXTERNAL ROOM THERMOSTAT on page 43 for more information). Using 

+

 and 

-

 you 

can switch between EXT OFF (inactive) and EXT ON (active).

Menü

GSM SET

All settings concerning Telephone option – GSM are made here. Pressing 

 takes you to the submenu of Telephone 

option – GSM. Please see the operating instructions accompanying the Telephone option – GSM for settings.

Menü

ROOM SET The room temperature displayed may deviate from the actual temperature and therefore the sensor may be calibrated by 

+/- 4°C. Thus the actual temperature of the room sensor can be adjusted e.g. to the house thermometer.

Menü

LOCK OFF

Display of operating status of additional function LOCK child safety device (key lock). Using 

+

 and 

-

 you can 

switch between LOCK OFF (inactive) and LOCK ON (active).
To lock the keyboard with active child protection device (LOCK ON), press 

+

 and 

-

 at the same time for at least 

5 seconds in the standard mode EASY or HEAT. LOCK appears in the display as confirmation. To unlock the keyboard 
again press 

+

 and 

-

 at the same time for at least 5 seconds. LOCK OFF appears in the display as confirmation.

Menü

RESET
-I:0-

Any settings changed can be reset to the delivery status here. Pressing 

 resets the stove to the factory settings.

Menü

SETUP

Display to enter the control level for additional functions. You can change between the operating status On (active) and 
OFF (inactive).

Menü

Repeated pressing of 

Menü

 returns you to the main menu level.

Summary of Contents for INDALO

Page 1: ...Bedienungsanleitung mit Aufstellanleitung en Operating manual with installation instructions fr Manuel d utilisation avec instructions de montage it Istruzioni per l uso e l installazione Pelletkamin...

Page 2: ...2 A...

Page 3: ...UNIT FUNCTION 34 INTERNAL CONTROL UNIT 34 SIMPLE HEATING OPERATION EASY MODE THE FIRST STEPS 34 EASY OFF INACTIVE STATE 34 START IGNITION PROCESS 35 EASY 40 OPERATION 35 EASY 40 SWITCH OFF 35 EXTENDE...

Page 4: ...PROTOCOL FOR PUTTING INTO OPERATION 48 15 MENU NAVIGATION OVERALL VIEW 49 16 PROGRAMMING HEATING TIMES 51 17 AFTER SALES SERVICE 52 18 WARRANTY 52 Slight variations in colour due to printing process S...

Page 5: ...aging of your new stove provides excellent protection against damage In spite of this the stove and accessories can be damaged during transport Dimensions on page 2 The owner of small firing systems o...

Page 6: ...is new pellets are a standard sets new benchmarks in the Euro pean pellet market The traceability of pellets is ensured thanks to the use of identification numbers The pellet manufacturers pro duction...

Page 7: ...the operating functions that were set before the power failure are continued After a brief power failure the operating functions set prior to the failure are continued If the power failure lasts long...

Page 8: ...nefficient combus tion Note Please note that problems may arise due to updrafts in the case of combustion air supply from an integrated chimney ventilation shaft If the combustion air flowing downward...

Page 9: ...by trained specialist dealers or the service department Improper handling of these parts leads to the guarantee and warranty becoming null and void INTERNAL CONTROL UNIT All settings and functions ca...

Page 10: ...this is replaced by START after a brief time EASY xx appears in the display after the start phase xx stands for a value between 30 and 100 depending on output If switching off occurs again 50 sec wit...

Page 11: ...fort function currently visible HEAT AUTO or ROOM In addition to the basic functions of simple heating operation the LOHBERGER pellet stove provides extra comfort functions However be fore you can use...

Page 12: ...d here Men Pressing Men once changes to display INFO INFO Access to information menu various system parameters temperatures and operating information can be called up here Men Pressing Men once change...

Page 13: ...The menu item TIME AUTO only appears in connection with the room sensor and the wireless room sensor Please see the operating instruction enclosed for the option for setting the heating times Men TIM...

Page 14: ...active in connection with a room thermostat The lock function is switched on or off by using the or key All the parameters set are reset to factory values by using the I O key Men Men The C Fan funct...

Page 15: ...ion GSM Please see the operating instructions accompanying the Telephone option GSM for settings Men ROOM SET The room temperature displayed may deviate from the actual temperature and therefore the s...

Page 16: ...ay of total amount conveyed in kg pellets Display of conveyed pellet amount since the last cleaning and maintenance in kg pellets Men Men Men Men Men Tip grate contact contact open closed No motor dri...

Page 17: ...ay of operating status of flue gas blower ON or OFF Men FAN 00 Display of speed of flue gas blower Men C FAN ON Display of the operating status of the cross flow fan ON or OFF Men C FAN 00 Display of...

Page 18: ...s room sensor for more detailed informa tion TELEPHONE OPTION GSM Your pellet stove can also be started via a mobile phone as an additional option Please see the operating instructions for the tele ph...

Page 19: ...should be looked at to ensure that ash or clinker does not block the air feed openings The fire pan can easily be cleaned inside the stove After removing the pan the area underneath can be vacuumed c...

Page 20: ...AS FAN The flue gas fan and its flue tube connection should be cleaned at least 2 x a year or after approx 700 kg pellets In order to inspect the flue gas fan and to clean it remove four screws and pu...

Page 21: ...allschacht wurde erkannt Die Fehlermeldung kann durch gleichzeitiges Dr cken der Men und Taste solange bis die Fehlermeldung erlischt quittiert werden Bei Auftreten unbedingt Kundendienst verst ndigen...

Page 22: ...off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into ope ration It is very important that the operator...

Page 23: ...ed GSM modem present Room thermostat present Function checked Exhaust line chimney Diameter Connection leakproof Bends Chimney draught Stove functions Pellet container filled Grill dumps 360 and remai...

Page 24: ...et the day using the and key Set the month using the and key Set the year using the and key Men Men Selection of comfort function required HEAT AUTO ROOM by pressing the I O key Heating time Men Men M...

Page 25: ...f Display of operating hours Display of total amount conveyed in kg pellets Display of conveyed pellet amount since the last cleaning and maintenance in kg pellets Display of current software version...

Page 26: ...per day MO TU WE TH FR SA SU can be set Start heating period 1 ON1 Change with and button in 10 min steps Stop heating period 1 OFF1 Change with and button in 10 min steps Start heating period 2 ON2 C...

Page 27: ...thermal stress Seals e g hardening or breakage due to thermal or mechanical stress Surface coatings frequent cleaning or cleaning with abra sive cleaning agents Cast iron parts Cast parts subjected to...

Page 28: ...sche nderungen vorbehalten Ausgabe April 2012 made in Austria Gepr ft nach DIN EN 12815 und sterr Art 15a B VG Erf llung strengster Umweltauflagen wie zB Regensburger Stuttgarter Norm M nchner Verordn...

Reviews: