SCRUB SINKS USE & INSTALLATION GUIDE
(800) 665-3760
16
|
INFRARED CONTROLS (FOR INFRARED SELF-ACTIVATED SINKS ONLY)
TROUBLESHOOTING
The sinks are supplied with a 24V power transformer(s) that connects to a standard duplex outlet (110/120V outlet required) 1-Station
sinks have one sensor, dual basin sinks have two sensors (one for each basin) and 3-Station sinks have
three sensors (one for each basin)
1 Plug the transformer(s) into the outlet
2 A red LED will flash in the sensor window (Fig 29 - circled in red)
IMPORTANT: Do not interrupt the sensor beam until the light turns off
OPERATION
The sensors are pre-set and equipped with a logic board The sensors determine the
range during the initialization period (The time after initial power until the light turns off
is approximately 5 minutes) The range is approximately 12-14” in front of the sensor
and is 25 degrees at peak
During the initialization period, the sensors allow for fixed objects that may be within the sensors’
range The sensors are equipped with a 2-second on/off delay, and no-time-out feature This
prevents the sink from turning on when walking past at a normal pace and no timeout allows for
an uninterrupted scrub
SOAP
;,
'
I
·
■
·
I
PLUMBING ACCESS
( MANUAL KNEE OPERATED SINKS ONLY)
1 Open the knee panel door by depressing the latch at the bottom of the panel door (Fig 24)
2 Swing the door fully open to access the hinges (Fig 25)
3 Push the hinge pins inward to release the door from the hinges (Fig 26) Infrared Controls (for Infrared Self-Activated Sinks only)
4 To re-attach the door, push in the hinge pins and fit the top corners of the knee panel door onto the left and right hinge leaves
(Fig 27 - circled in red) When the door is refitted, release the hinge pins to secure the door to the sink
5 The knee panel door should rotate freely on its hinges Rotate the door back down on its bottom latch to close it (Fig 28)
Fig 24 - Push Down Knee
Panel Door Latch
Fig 25 - Door in Fully
Opened Position
Fig 26 - Push Hinges Inward
Fig 27 - Left /Right Hinge Leaves
SOAP
;,
'
I
·
■
·
I
SOAP
;,
'
I
·
■
·
I
Fig 28 - Door Should
Rotate Freely on Hinges
Fig 29 - Location of Infrared Sensor