SCRUB SINKS USE & INSTALLATION GUIDE
www logiquip com
|
13
CONNECT DRAINPIPE TO DRAIN AND PLUMBING TO WATER LINES
IIccoonn TTyyppee
IIccoonn
D
Deessccrriippttiioonn
W
Waarrnniinnggss
(Red triangle with an exclamation point) indicate the potential for minor to
severe injuries up to and including death to personnel.
CCaauuttiioonnss
(Yellow triangle with an exclamation point) indicate the potential for minor
injury to personnel and damage to equipment.
Note: The exclamation point will not be visible where only equipment damage
is present.
B
Buurrnn H
Haazzaarrdd W
Waarrnniinnggss
(Yellow triangle with radiating lines) indicate a potential burn injury to personnel.
EElleeccttrriiccaall W
Waarrnniinnggss
(Yellow triangle with a lightning bolt) indicate a possible shock hazard is present.
Severe shock hazards shall be a lightning bolt in a red triangle.
Local building or plumbing codes may require modifications to the information provided You are required to consult the local
building and plumbing codes before installation If the information provided here is not consistent with your local building or plumbing
codes, the local codes should be followed This product must be installed by a licensed contractor in accordance with local codes and
ordinances
IIccoonn TTyyppee
IIccoonn
D
Deessccrriippttiioonn
W
Waarrnniinnggss
(Red triangle with an exclamation point) indicate the potential for minor to
severe injuries up to and including death to personnel.
CCaauuttiioonnss
(Yellow triangle with an exclamation point) indicate the potential for minor
injury to personnel and damage to equipment.
Note: The exclamation point will not be visible where only equipment damage
is present.
B
Buurrnn H
Haazzaarrdd W
Waarrnniinnggss
(Yellow triangle with radiating lines) indicate a potential burn injury to personnel.
EElleeccttrriiccaall W
Waarrnniinnggss
(Yellow triangle with a lightning bolt) indicate a possible shock hazard is present.
Severe shock hazards shall be a lightning bolt in a red triangle.
FAILURE TO COMPLY WITH PROPER INSTALLATION AND MAINTENANCE INSTRUCTIONS COULD CONTRIBUTE TO VALVE FAILURE.
This hot water master tempering valve cannot be used for tempering water temperature at fixtures Severe bodily injury (i e , scalding
or chilling) and/or death may result depending upon system water pressure changes and/or supply water temperature changes ASSE
standard 1016, 1069, or 1070 listed devices should be used at fixtures to prevent possible injury
This hot water tempering valve is designed to be installed at or near the boiler or water heater They are not designed to compensate for
system pressure fluctuations and should not be used where ASSE standard 1016, 1069, or 1070 devices are required These valves
should never be used to provide “anti-scald” or “anti-chill” service
The components of the system must be of materials with a construction capable of withstanding the high limit output temperatures of
the water heating source
IIccoonn TTyyppee
IIccoonn
D
Deessccrriippttiioonn
W
Waarrnniinnggss
(Red triangle with an exclamation point) indicate the potential for minor to
severe injuries up to and including death to personnel.
CCaauuttiioonnss
(Yellow triangle with an exclamation point) indicate the potential for minor
injury to personnel and damage to equipment.
Note: The exclamation point will not be visible where only equipment damage
is present.
B
Buurrnn H
Haazzaarrdd W
Waarrnniinnggss
(Yellow triangle with radiating lines) indicate a potential burn injury to personnel.
EElleeccttrriiccaall W
Waarrnniinnggss
(Yellow triangle with a lightning bolt) indicate a possible shock hazard is present.
Severe shock hazards shall be a lightning bolt in a red triangle.
Need for Periodic Inspection and Yearly Maintenance:
Periodic inspection and yearly maintenance by a licensed contractor are
required Corrosive water conditions, temperatures over 200°F, unauthorized adjustments or repairs could render the valve ineffective
for the service intended Regular checking and cleaning of the valve’s internal components and check stops helps assure maximum life
and proper product function Frequency of cleaning and inspection depends upon local water conditions
PLUMBING INSTALL INSTRUCTIONS
Plumbing Installation should be in accordance with accepted plumbing practices Installation and field adjustment are the
responsibility of the installer
1 Flush all pipes thoroughly before installation
2 Connect sink drainpipe to drain connection
3 Close both hot and cold water shutoff valves upstream of the tempering valve
4 Bleed pressure from the system
5 Route copper tubing or piping to fit valve dimensions
6 Remove tailpieces from the valve and make sure union nuts are over the tubing/piping before connecting to the tailpiece
Note: If soldering, remove unions and gaskets from the valve body before soldering to prevent damage to the valve from
excessive heat
7 Flush piping again, install valve using filter gasket on hot and cold water inlets and fiber gasket on the mixed water outlet
8 Turn on the cold and hot water If any leaks are observed, tighten connections as necessary to stop leaks before proceeding
9 After the plumbing installation is complete, the water pressure can be adjusted to avoid excess splash The pressure can be
controlled by adjusting the flow with the flow control valve See Item #4 of the plumbing diagram for the manual knee operated
plumbing on page 15
10 Feed the spout (Item #1)
through the small hole at the top of the sink (Item #9) The nut (Item #2) should rest on top of the sink
11 Re-install the bushing onto the spout from inside the cabinet (Fig 10) as shown on page 10
12 Attach the soap tubing to the spout and soap pump (circled in red) as shown in Fig 11 and Fig 12 on page 10