18
Battle Ax Light - Skid Loader OM
Lubrication (Cont’d)
Grease Points Location (Cont’d)
2
Location:
Right side rotor bearing (2).
Interval:
Every 8 hours of operation.
NOTE:
Rotor bearings cannot be damaged by over-
greasing. Lubricate the fittings until a small
amount of grease is purged from the bearing.
Maintenance
Overhung Load Adapter
Cover must be removed to access the overhung load
adapter. Refer to“Removing Motor Cover, Manual Holder
Cover, and Hose Cover” on page 20 for instructions.
2
1
Remove the plug from the port (1) located on the top of
the overhung load adapter, and the plug from the lower
port (2) located on the back side.
Partially tilt the Battle Ax Light back towards the skid
steer to drain the hydraulic oil.
Reinsert the lower plug and tighten.
Using a funnel placed into the top port of the overhung
load adapter, add 4 oz. of universal hydraulic fluid.
Return the plug back into the top port and tighten.
NOTE:
If replacing bearings or seals in the overhung
load adapter, be certain to refill with hydraulic
fluid after reassembly.
Summary of Contents for Battle Ax Light
Page 2: ......
Page 4: ......
Page 8: ...2 Battle Ax Light Skid Loader OM...
Page 32: ...26 Battle Ax Light Skid Loader OM...
Page 33: ...27 Battle Ax Light Skid Loader OM PARTS IDENTIFICATION Parts Identification...
Page 57: ...51 Battle Ax Light Skid Loader OM Appendix Torque Specifications Inches Hardware and Lock Nuts...
Page 59: ......