14
3N1
CABLING OF THE SECTION ELECTRONIC (SE)
Cabling of the Section Electronic (SE)
Yellow: LAN to SE-boards (splitter on each section)
Black: Power supply (from Power supply of RIFA)
Red: Stop cable IF to connect the SAG)
Blue: Ground from SE to machine ground
For exact cabling see the following description. Before starting with the cabling the sensors should be fitted!
View from below
Machine Head
First Section
Last Section
SE LOEPFE
SE LOEPFE
Empty
Electronic Board
RIFA
PLC Controller
Power
SCU
n-11 n
1 24
1 24
n-11 n
Ground
LAN-Communication