Dispensing
5
5.2
Refilling the Product Reservoir
5.2.1
Product Reservoir with Low Level Sensor (Automatic Reservoir)
Error message „
--- Refill ---
“
(see Chapter 7):
The error message display blinks.
●
Prepare product for refilling.
Error message „
--- Empty ---
“ with beeping:
The error message display blinks. The dispensing
sequence is interrupted and no further dispensing
sequence can be started.
●
Press the button
to stop the beeping.
☞
The automatic reservoir
97106 / 97108
is automatically depressurized following the empty message.
●
Refill the automatic reservoir according to its instruction manual and reconnect.
Error message
„
PRESS ENTER
>Tank Inactive<
“
(product reservoir (
Tank
) not pressurized):
●
Press button
once (
PRESS ENTER
). The
automatic reservoir is pressurized.
The error message „
Press. 0.83 NOK
“
(
Press.
= Dispensing pressure)
blinks in the digital display with beeping.
The value
0.83
[bar/psi] is only an example for
the indication of the dispensing pressure (see Chapter 7).
☞
The error message „Press 0.83 NOK“ with beeping
disappears by itself
when the dispensing
pressure in the product reservoir does not deviate more than 10 % from the stored comparison value
of the automatic pressure control.
After the error message „
Press. 0.83 NOK
“ with beeping has disappeared:
●
Continue dispensing with the stored values for dispensing time and pressure.