Technical Data
3
3.1
Energy Requirements
3.1.1
Electrics
Power supply
90 – 260 VAC; 47 – 63 Hz
Power consumption
Approx. 40 W
Power protection
Glass tube, fine wire fuse, 2 AM
Internal control voltages
5 VDC; 12 VDC; 24 VDC
3.1.2
Pneumatics
Pneumatic supply
min. 2 bar (29 psi); max. 12 bar (174 psi)
Quality
Filtered 10 µm, oil-free, non-condensing
If the required quality is not achieved,
install a LOCTITE filter regulator.
Accessory Order No. 97120
Regulation range of the pressure regulator
0.00 – 7.00 bar (0.00 – 100 psi)
Pressure indication
0.00 – 7.00 bar (0.00 – 100 psi)
3.2
Connections and Dimensions
Power connection
Cold appliance coupl. IEC 320 acc. to VDE 0625
(Dispensing Valve)
(Product reservoir)
Dimensions
W x H x D: 145 x 230 x 260 mm
3.3
Other Data
Protection grade
IP 33 acc. to VDE 0470, Part 1 / EN 60529-1991
Operating temperature
+10 °C to +40 °C (+50 °F to +104 °F)
Storage temperature
-10 °C to +60 °C (+14 °F to +140 °F)
Weight
2,8 kg
Continuous sound pressure level
< 70 dB(A)
35
+0.0 5
--0.10
External dia.
Pneum. hose size Control air conn.
Pneumatic hose size Pneumatic supply
Internal dia. 2.5 mm; external dia. 4 mm
9.5 mm, TW09 B-20, SMC