Block Not Found on computer
Protection Block must be plugged in properly.
Machine moves rapidly when Auto Zeroing X-
axis, followed by screen message:
Axes: X
Following Error Exceeded
Check encoder cable.
Torch will not raise or lower
1. Check for any binding at torch lifter with
power off.
2. Check air pressure. Minimum air pressure
must be 40 psi.
3. Check for 24 VDC at lifter assembly. If "yes",
replace the 4-way valve. If "no", check cable
and fuses on back of controller.
Torch head goes up and down too fast or too
slow.
Adjust the screw on the two brass muffler on
the four-way valve. NOTE: The top screw is
for moving up, and the bottom screw is for
moving down.
Torch Movement