Instruction manual CH
55
s
3. Undo the bolts.
4. Remove the lid, the gasket and the O-ring.
5. Inspect the tank and remove the loose scale deposits and contamination.
6. If the scale cannot be removed by hand, descale the appliance with a
descaling agent. Contact the supplier/manufacturer for advice on what
descaling agent to use.
7. Close the cleaning opening. To avoid damage to the tank, tighten the bolts
that fasten the lid with a torque no greater than 50 Nm. Use suitable tools for
this. To seal the cleaning opening properly, we recommend tightening the
bolts in the sequence shown in the diagram.
12.4 Gas-side
maintenance
12.4.1
Introduction
The following steps must be carried out on the gas side:
1.
Clean the burner(s)
.
2.
Clean the orifice(s)
.
3.
Checking the flue baffles
.
12.4.2
Clean the burner(s)
1. Detach the burner(s)
2. Remove all contamination present on the burner(s).
3. Fit the burner(s)
12.4.3
Clean the orifice(s)
1. Detach the orifice(s)
2. Remove all contamination present in the orifice(s).
3. Fit the orifice(s)
12.4.4
Checking the flue baffles
Warning
The flue baffles can be hot.
1. Remove the flue baffles from the appliance.
2. Check the flue baffles for the presence of corrosion, removing this if
necessary.
3. Check the flue baffles for wear, and replace the flue baffles if necessary.
1
3
6
2
4
5
IMD-0282 R1
Summary of Contents for CH 100 CE
Page 4: ...4 Instruction manual CH gis...
Page 10: ...Introduction 10 Instruction manual CH 1 gis...
Page 16: ...Working principle of the water heater 16 Instruction manual CH 2 gis...
Page 36: ...Conversion to a different gas category 36 Instruction manual CH 4 is...
Page 44: ...Status of the water heater 44 Instruction manual CH 8 gis...
Page 46: ...Starting the water heater 46 Instruction manual CH 9 gis...
Page 48: ...Shutting down 48 Instruction manual CH 10 gis...
Page 62: ...Electrical diagram 62 Instruction manual CH 14 is...
Page 64: ...Declaration of Conformity 64 Instruction manual CH 15 is...