0433-INS-400
Rev.
E
6-11
Weld Summary Screen
The
Weld Summary
displays a table of stored
weld summary data records (Rtype 2), with the
most current record at the top.
Use the arrow keys to scroll through the rows (data
records) and columns (data parameters).
To determine the parameters that were out of
tolerance in a given row (weld data record), pick
that row and press the SELECT key. A pop-up
window will display the offending parameters, as
shown in figure 6-16. Use ESCAPE to close the
pop-up window.
To view the weld tolerance limits for a specific
parameter, navigate to the data for that parameter
and press the SELECT key. A pop-up window will
display the weld tolerance limits. Use ESCAPE to
close the pop-up window.
In addition to many of the Halfcycle Summary
parameters described in the previous section, the
Weld Summary
parameters also include the
following:
•
Weld
The weld number, with the most recent at the
top.
•
Hcycles On
Number of halfcycles in the weld that actually had current flow.
Note:
The
Rtype
field is omitted because all weld summary records have the same record type (2).
Weld summary data records are also shown in the Halfcycle Summary table.
Figure
6-15
Weld Summary
Figure
6-16
Pop-up window displaying all
parameters that were out of tolerance
Summary of Contents for WELDWISE 2400
Page 1: ...Revision C 001 User s Manual WeldWise 2400 THE WELD MONITORING SPECIALISTS TM...
Page 2: ......
Page 34: ...4 6...
Page 46: ...5 12...
Page 94: ...6 48...
Page 104: ...7 10...
Page 116: ...9 4...
Page 146: ...10 30...
Page 164: ...0340 DWG 400 Rev C 11 18...
Page 165: ...0308 DWG 400 Rev D 11 19...
Page 168: ...11 22...
Page 176: ...0454 APP 118 Rev A 12 6...
Page 194: ...13 2...