0432-INS-400 Rev E.
5- 11
Figure
5-20
Halfcycle Summary for ACCEPTED
weld
Figure
5-21
Main program screen displaying a
REJECTED weld (
Current Rms
, etc. too low)
Figure
5-22
Halfcycle Summary for REJECTED
weld
7. Decrease the heat on your weld schedule by 20.
(If your schedule is set for 45% heat, lower it to
25% heat). ESCAPE to the main screen and
make a weld.
8. The
Weld Status
box should display flashing
arrows, indicating a REJECTED weld, as shown
in figure 5-21. Go to the
Halfcycle Summary
screen. It should look similar to figure 5-22.
Notice that the
Current Rms
line is below the
lower tolerance boundary, causing a
REJECTED weld.
Summary
Remember, this guide is intended as an example
only— the creation of masters and tolerances for
individual weld processes will vary. Please refer to
Chapter 6, WMS Reference Guide for a complete
description of all functions in the WMS program, or
use Chapter 10, Troubleshooting Guide for more
information about mastering.